Cardinal Health Argyle Turkel Safety Thoracentesis System. Spring loaded blunt safety cannula extends beyond needle tip. One-way valve in needle housing. Color change indicator to identify blunt cannula position. Ball valve in catheter housing. In-line stop cock. Polyurethane catheter-over-needle design. 1cm depth marks on catheter shaft. Multiple side holes on catheter shaft. Sterile.
SKU MPN OPTION DESCRIPTION EST. TO SHIP
CDL-566034-- 566034-- Safety Thoracentesis System, 8FR Catheter, 2.7mm O.D., 3½"L, 20/bx, 8 bx/cs Safety Thoracentesis System, 8FR Catheter, 2.7mm O.D., 3½"L, 20/bx, 8 bx/cs (Continental US Only) (Item on Manufacturer Backorder - Inventory Limited when Available) 1-2 Weeks
CDL-566075 566075 Argyle Turkel Safety Thoracentesis Procedure Tray with Safety Components, Catheter, 8 FR, 2.7 mm , 5" Length, 1/tray, 5 tray/cs (60-Day Dating; Non-Returnable) Argyle Turkel Safety Thoracentesis Procedure Tray with Safety Components, Catheter, 8 FR, 2.7 mm , 5" Length, 1/tray, 5 tray/cs (60-Day Dating; Non-Returnable) (Continental US Only) 1-2 Weeks
CDL-566059 566059 Argyle Turkel Safety Thoracentesis Procedure Tray with Safety Components, Catheter, 8FR, 2.7mm , 3.5" Length, Sterile, 5 tray/cs Argyle Turkel Safety Thoracentesis Procedure Tray with Safety Components, Catheter, 8FR, 2.7mm , 3.5" Length, Sterile, 5 tray/cs (Continental US Only) (Item on Manufacturer Backorder - Inventory Limited when Available) 1-2 Weeks

Frequently asked questions

Does the system use a spring-loaded safety cannula?

Yes, the Argyle Turkel Safety Thoracentesis System is engineered with an integrated, advanced safety mechanism to significantly minimize the risk of accidental needlestick injuries.

This crucial safety feature includes:

  • A spring-loaded blunt safety cannula that automatically extends beyond the sharp needle tip upon withdrawal.
  • A color change indicator system that provides clear visual confirmation of the blunt cannula’s safe, extended position, ensuring procedural visibility and confidence.
Does the system feature a visual safety indicator?

Yes, the Cardinal Health Argyle Turkel Safety Thoracentesis System is specifically engineered with a crucial visual safety mechanism for enhanced procedural safety and confidence.

  • Color Change Indicator: The system utilizes a color change indicator to provide immediate, definitive visual feedback.
  • Safety Confirmation: This indicator clearly signals the exact position of the spring-loaded blunt safety cannula.
  • Automatic Protection: By confirming that the blunt cannula has automatically extended beyond the needle tip, the system minimizes the risk of accidental needlestick injuries.
Does the system include precise fluid control valves?

Yes, the Argyle Turkel Safety Thoracentesis System is engineered for precise and controlled fluid management during procedures. It utilizes multiple components for comprehensive fluid regulation:

  • One-Way Valve: Located within the needle housing to help prevent backflow.
  • Ball Valve: Integrated into the catheter housing for controlled fluid dynamics.
  • In-Line Stop Cock: Each system includes an in-line stop cock for convenient and easy flow regulation during aspiration or drainage.
Is the thoracentesis system supplied sterile?

Yes, the Cardinal Health Argyle Turkel Safety Thoracentesis System is provided sterile, ensuring maximum safety and readiness for clinical procedures. This product is designated as Factory New.

Does the system ensure controlled fluid management?

Yes, the Argyle Turkel Safety Thoracentesis System is designed with multiple integrated features to ensure controlled and efficient fluid management:

  • Dual Valve System: Fluid flow is regulated by a specialized dual valve setup:
    • A one-way valve is located in the needle housing.
    • A ball valve is situated in the catheter housing.
  • Optimized Drainage: The durable polyurethane catheter features multiple side holes along its shaft to enhance fluid aspiration and drainage efficiency.
  • Flow Regulation: Each system includes an in-line stop cock for manual flow control during the procedure.
  • Precision Placement: The catheter shaft is marked with 1cm depth increments to help ensure accurate placement, which is vital for effective fluid removal.
Is a spring-loaded blunt safety cannula used?

Yes, the Cardinal Health Argyle Turkel Safety Thoracentesis System is engineered with an advanced safety mechanism centered around a spring-loaded blunt safety cannula.

This design ensures maximum safety for both the patient and the clinician by offering two critical features:

  • Automatic Protection: The blunt safety cannula automatically extends and deploys beyond the needle tip upon withdrawal, significantly reducing the risk of accidental needlestick injury.
  • Safety Confirmation: The system utilizes a color change indicator that provides clear, visual confirmation of the blunt cannula’s position, ensuring it is securely in the safe, engaged state.
Does the catheter feature depth marks and multiple side holes?

Yes, the Argyle Turkel system is built with a high-specification polyurethane catheter featuring elements designed for control and effective fluid management.

Key features of the catheter include:

  • Optimal Drainage: It is equipped with multiple side holes along the shaft to ensure efficient fluid aspiration and drainage during the procedure.
  • Precision Guidance: Clear 1cm depth marks are present on the catheter shaft to assist medical professionals in accurately assessing and confirming placement depth.
What catheter lengths are available?

Yes, the Cardinal Health Argyle Turkel System is available in configurations offering two specific catheter lengths to accommodate diverse procedural needs:

  • 3½ inches
  • 5 inches

The catheter itself is made from durable polyurethane and is designed with multiple side holes for efficient fluid removal, along with 1cm depth markings on the shaft for precise depth assessment.

What are the catheter's key specifications?

The Argyle Turkel Safety Thoracentesis System utilizes a robust, sterile polyurethane catheter-over-needle design.Key specifications and features of the catheter include:* Construction: Durable polyurethane material.* Fluid Access: Features multiple side holes on the shaft to ensure effective fluid aspiration and drainage.* Depth Control: Includes precise 1cm depth marks on the shaft to assist with accurate placement assessment.* Valve System: The catheter housing is equipped with a reliable ball valve for secure fluid management.The system is available in various sizes and lengths, such as 8FR catheter (2.7mm O.D.) and catheter lengths of 3” or 5”.

Does the catheter have accurate depth markings?

Yes, the Argyle Turkel Safety System features a highly functional polyurethane catheter designed for precision and effective fluid management during thoracentesis.

Key features of the catheter include:

  • 1cm Depth Marks: The catheter shaft is clearly marked with 1cm depth increments to aid practitioners in maintaining procedural accuracy and controlling insertion depth.
  • Multiple Side Holes: These are incorporated into the catheter shaft to ensure optimal fluid aspiration and drainage efficiency.