- Condition: Factory New
- Country of Origin: Mexico
- Warranty: 1 Year
- Weight: 4.05 lb
- Designed for use with PlumaSafe Turbo and Porta PlumeSafe 604 Evacuators
- Long operation time allows for up to 18 hours of smoke evacuation
- Dual male ports (7/8" and 1-1/4")
- Integrates four stages of filtration: a pre-filter, activated carbon, an ULPA filter for 99.999% efficiency down to 0.1 - 0.2 micron, and a post-filter
-
Learn more:
- MFR: Buffalo Filter Ships from Manufacturer
- MPN: VSXLL02
- Phone: (866) 426-6633
Frequently asked questions
Does the filter include dual male connection ports?
Yes, the Buffalo Filter ViroSafe XLL Filter is equipped with dual male ports for broad compatibility and easy integration with PlumaSafe Turbo and Porta PlumeSafe 604 Surgical Smoke Evacuators.Key details regarding the ports:* Sizes: The dual ports measure 7/8” (0.875”) and 1-1/4” (1.25”).* Safety Feature: The design includes hidden ports specifically to minimize potential cross-contamination risks to caregivers and operating room personnel during filter handling.
Does this filter offer up to 18 hours of operation?
Yes, the ViroSafe XLL (Extra Long Life) filter is engineered for extended operational time.
It provides up to 18 hours of continuous smoke evacuation, which is a key benefit for maintaining workflow efficiency and minimizing the frequency of replacements in a clinical setting.
Does the ViroSafe XLL Filter include a warranty?
Yes, the Buffalo Filter ViroSafe XLL Filter comes with a 1-year warranty.
What package quantity options are available?
The Buffalo Filter ViroSafe XLL Filter is available in three package quantities to suit your operational needs:
- Single Filter Unit
- Case of 2 Filters
- Case of 4 Filters
Which smoke evacuation units is this filter compatible with?
The ViroSafe XLL Filter is engineered for use with specific Buffalo Filter surgical smoke evacuation systems to ensure peak performance and safety. It is compatible with:
- PlumaSafe Turbo Surgical Smoke Evacuator
- Porta PlumeSafe 604 Surgical Smoke Evacuator
For enhanced versatility, the filter unit features dual male ports measuring 7/8” (0.875”) and 1-1/4” (1.25”) to accommodate various tubing connections.
Is a high-efficiency ULPA filter included?
Yes, the ViroSafe XLL Filter features an advanced, integrated four-stage filtration system which includes a high-efficiency ULPA (Ultra Low Penetration Air) filter.
This system is designed for superior air quality during surgical procedures:
- ULPA Efficiency: Achieves 99.999% efficiency.
- Particle Capture: Effective down to particles measuring 0.1 to 0.2 microns.
The four stages of filtration are: Pre-filter, Activated Carbon (for odor absorption), ULPA filter, and Post-filter.
What are the four stages of the advanced filtration system?
The Buffalo Filter ViroSafe XLL utilizes a robust, integrated 4-stage filtration system designed for comprehensive surgical smoke evacuation. This filtration complexity is key to its Extra Long Life (XLL), offering up to 18 hours of continuous operational time.
The four stages included in the single housing unit are:
- Pre-filter: Captures larger airborne particles to protect the subsequent high-efficiency media.
- Activated Carbon: Effectively neutralizes and adsorbs chemical toxins, harmful gases, and odors present in the smoke stream.
- ULPA Filter (Ultra-Low Penetration Air): This critical high-efficiency stage captures sub-micron particles with an exceptional 99.999% efficiency down to 0.1 to 0.2 microns.
- Post-filter: Serves as the final safety layer, ensuring only thoroughly purified air is exhausted.
Does this filter minimize cross-contamination risks?
Yes, the Buffalo Filter ViroSafe XLL filter is specifically engineered to minimize cross-contamination risks for caregivers.This safety feature is primarily achieved through the use of hidden ports within the filter housing, which helps minimize potential contact between staff and captured contaminants during handling and disposal.Furthermore, the unit employs a robust 4-stage filtration system, including a high-efficiency ULPA filter (99.999% efficiency down to 0.1–0.2 micron), ensuring comprehensive capture of particulates.
What size are the dual male ports?
The Buffalo Filter ViroSafe XLL Filter features versatile dual male ports designed to ensure compatibility with specified surgical smoke evacuation units.
The sizes of the two connection ports are:
- 7/8 inch (0.875”)
- 1-1/4 inch (1.25”)
This configuration allows for seamless connection to compatible systems, such as the PlumaSafe Turbo and Porta PlumeSafe 604 Surgical Smoke Evacuators.
Does this filter maintain high air quality standards?
Yes, this filter is highly effective at maintaining air purity in clinical settings. It features an advanced 4-stage filtration system designed to capture hazardous particulates and odors:
- Pre-filter: Captures larger debris.
- Activated Carbon: Effectively absorbs surgical smoke odors and gases.
- ULPA Filter: Achieves a 99.999% efficiency rating for particles as small as 0.1 to 0.2 microns.
- Post-filter: Provides final stage purification.
This robust design ensures comprehensive protection and air quality management during surgical procedures.