Sale price$182.80
Select a Configuration

Special Order Item

Est. Delivery: 
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

Bd Vacutainer Acd Glass Tubes.
SKU MPN OPTION DESCRIPTION EST. TO SHIP
BDM-364606 364606 Conventional Stopper, 16 x 100mm, 8.5mL, Yellow, Paper Label, ACD Solution A of Trisodium Citrate 22.0g/L, Citric Acid 8.0g/L & Dextrose 24.5g/L, 1.5mL, 100/bx Glass Tube, Conventional Stopper, 16 x 100mm, 8.5mL, Yellow, Paper Label, ACD Solution A of Trisodium Citrate 22.0g/L, Citric Acid 8.0g/L & Dextrose 24.5g/L, 1.5mL, 100/bx (Minimum Expiry Lead is 90 days) (Continental US Only) (Item on Manufacturer Backorder - Inventory Limited when Available)  Max weekly quantity allowed: 10 (Drop Ship Requires Pre-Approval)  Max weekly quantity allowed: 10 1-2 Weeks
BDM-364816 364816 Conventional Stopper, 13 x 100mm, 6.0mL, Yellow, Paper Label, ACD Solution B of Trisodium Citrate 13.2g/L, Citric Acid 4.8g/L & Dextrose 14.7g/L, 1.0mL, 100/pk, 10 pk/cs Glass Tube, Conventional Stopper, 13 x 100mm, 6.0mL, Yellow, Paper Label, ACD Solution B of Trisodium Citrate 13.2g/L, Citric Acid 4.8g/L & Dextrose 14.7g/L, 1.0mL, 100/pk, 10 pk/cs (Minimum Expiry Lead is 90 days) (Temp Sensitive; Non-Returnable) (Continental US Only) 3-5 Business Days

Frequently asked questions

How does the ACD solution stabilize blood samples?

The Acid Citrate Dextrose (ACD) solution is essential for specialized laboratory procedures, such as cellular studies and diagnostic testing, as it preserves whole blood samples by providing both anticoagulation and cellular component stabilization.

Here is how the ACD components function:

  • Anticoagulation: The citrate components (Trisodium Citrate and Citric Acid) prevent blood clotting by binding to and inactivating the calcium ions necessary for the coagulation cascade.
  • Cellular Viability: The dextrose component serves as a nutrient source, crucial for maintaining the stability and viability of blood cells throughout the necessary storage period.

BD offers two distinct formulations to accommodate varying laboratory requirements:

  • ACD Solution A: This formulation contains higher concentrations of Trisodium Citrate, Citric Acid, and Dextrose.
  • ACD Solution B: This formulation contains lower concentrations of the ACD components.
Are these Vacutainer tubes made of high-quality glass?

Yes, these BD Vacutainer tubes are constructed from high-quality glass, which is the material of choice for specialized blood collection requiring ACD preservation. Glass ensures critical sample integrity and stability.

Key features of these tubes include:

  • Anticoagulant Stability: The glass construction provides optimal chemical compatibility for the Acid Citrate Dextrose (ACD) solutions (A or B).
  • Condition and Design: They are guaranteed to be factory new, feature conventional stoppers, and are manufactured by BD.
  • Available Sizes: The tubes come in two primary sizes: 8.5mL (16 x 100mm) and 6.0mL (13 x 100mm).
Are multiple ACD solution options available?

Yes, these BD Vacutainer tubes are available with two distinct ACD (Acid Citrate Dextrose) solution formulations, allowing flexibility for professional use based on required stabilization needs.

ACD is used to preserve whole blood for cellular studies by providing anticoagulation and preserving cellular components. The available formulations differ in concentration and are paired with specific tube sizes:

Feature ACD Solution A ACD Solution B
Tube Size 16 x 100mm (8.5mL) 13 x 100mm (6.0mL)
Trisodium Citrate 22.0 g/L 13.2 g/L
Citric Acid 8.0 g/L 4.8 g/L
Dextrose 24.5 g/L 14.7 g/L
Do these specialized ACD tubes require special handling?

Yes, these specialized BD Vacutainer ACD Glass Tubes require specific handling and adherence to certain procurement requirements:

  • Temperature Sensitivity: The larger 8.5mL tube (ACD Solution A) configuration is designated as temperature sensitive. Appropriate storage and transport are essential for preserving the integrity of the anticoagulant solution.
  • Non-Returnable Status: Please note that the 8.5mL variant is also marked as non-returnable.
  • Geographic Restriction: The 6.0mL variant (ACD Solution B) is currently available for shipment within the Continental US Only.
  • Procurement Restrictions (8.5mL Variant): This variant has a maximum weekly purchase limit of 10 units and may require Drop Ship Pre-Approval due to specific handling logistics.
What packaging options are offered?

The BD Vacutainer ACD Glass Tubes are available in two distinct packaging configurations, depending on the specific size and ACD solution:

  • For the 16 x 100mm, 8.5mL tubes (ACD Solution A): These tubes are packaged in boxes of 100 tubes per box (100/bx).
  • For the 13 x 100mm, 6.0mL tubes (ACD Solution B): These tubes are sold in individual packs of 100 tubes per pack (100/pk). They are also available in bulk cases containing 10 packs per case (10 pk/cs), which results in a total of 1,000 tubes.
What kind of stopper do these tubes have?

The BD Vacutainer ACD Glass Tubes feature a conventional stopper and a paper label.

Is drop ship pre-approval required?

Yes, drop ship requires pre-approval for certain configurations of the BD Vacutainer ACD Glass Tubes. This ensures proper handling and adherence to specific shipping requirements.

What are the primary uses for these ACD glass tubes?

The BD Vacutainer ACD (Acid Citrate Dextrose) Glass Tubes are diagnostic collection devices designed for applications requiring whole blood stabilization, where maintaining cell viability and preventing clotting is critical.

These tubes are ideal for specific laboratory procedures, including:

  • Cellular assays
  • HLA testing (Human Leukocyte Antigen testing)
  • Blood bank processing

The tubes utilize the ACD additive system, which functions as both an anticoagulant and a cellular preservative. They are available with two distinct formulations to meet various requirements:

  • ACD Solution A: Higher concentration, suitable for specific preservation needs (e.g., in the 8.5mL variant).
  • ACD Solution B: Lower concentration, also designed for specific diagnostic applications (e.g., in the 6.0mL variant).
Are there different tube sizes available?

Yes, these BD Vacutainer tubes are available in two configurations, each featuring a different size, draw volume, and specific ACD solution type:

  • 16 x 100mm tube size, accommodating an 8.5 mL blood draw (with ACD Solution A).
  • 13 x 100mm tube size, accommodating a 6.0 mL blood draw (with ACD Solution B).
What are the available tube dimensions and volumes?

The BD Vacutainer ACD Glass Tubes are available in two specific dimensions, each corresponding to a different draw volume and ACD solution concentration:

  • 16 x 100mm tube: This configuration offers an 8.5mL draw volume and contains ACD Solution A.
  • 13 x 100mm tube: This configuration offers a 6.0mL draw volume and contains ACD Solution B.