Regular price$4,920.00 Sale price$4,099.59
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Baxter ELI 280 Resting Electrocardiograph includes current software, an AHA 10 wire, 12-lead lead set with banana plugs, ECG clip adapters (set of 10) and CardioSens Ultra II resting tab electrodes (pouch of 100), starter pack 8.5" x 11" letter paper, and US/Canada power cord.

Warranty:

  • Standard Models: 27 Months.
  • DICOM Models: 2 Years.

The ELI 280 Resting ECG provides comprehensive functionality in a portable, touchscreen device. The easy to use system easily meets the demands of high-volume ECG environments in both acute care and physician office environments.

Features

Baxter ELI 280 Resting Electrocardiograph Features

  • Easily integrates with your practice and data management systems for increased efficiency and optimized workflow.
  • Widescreen data layout allows for easy menu navigation, fast entry of patient information, and clear verification of proper electrode connections.
  • Best 10 feature automatically selects and displays the best 10 seconds of ECG data from memory, reducing the need for repeat ECGs caused by patient movement or other sources of ECG artifact.
  • VERITAS Resting ECG Interpretation Algorithm uses gender-specific, adult, and pediatric criteria to provide a silent second option for resting ECG interpretation. It displays hook-up confirmation which includes detection of lead reversals.
  • 10.1" high-resolution color touchscreen LCD displays up to 12 leads of ECG data for immediate review and plotting and 13 seconds of high-resolution ECG capture.
  • Internal storage for up to 200 ECGs; standard PDF capabilities through LAN or optional WiFi connection.
  • Easy bidirectional communication between EHR/HIS systems.
  • WAM Wireless Acquisition Module (optional): Equivalent in size and weight to a conventional wired patient cable, the WAM provides freedom of movement for the clinician while acquiring electrocardiograms and during cardiac stress testing. With the Wireless Acquisition Module, the ECG no longer needs to be right at the patient's bedside; this is particularly advantageous in critical situations or when the patient is in isolation.
    • Dedicated, secure communication links the module to a single ECG/cardiac stress testing system.
    • Full diagnostic-quality ECG with a high-fidelity acquisition sampling rate of 40,000 samples per second per channel - a benefit for accurate pacemaker detection.
    • Elimination of the cable reduces a source of artifact, resulting in high-quality ECG tracings.
    • On/off, 12-lead ECG acquisition and rhythm printing at the bedside with the simple press of a button.

Specifications

Baxter ELI 280 Resting Electrocardiograph Specifications

  • Weight: 13.9 lb (6.3 kg) including battery (without paper).
  • Dimensions: 15.5" x 17" x 4" (39.4 cm x 43.2 cm x 10.2 cm).
  • Instrument Type: Multi-lead electrocardiograph.
  • Input Channels: Simultaneous acquisition of all 12 leads.
  • Standard Leads Acquired: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6.
  • Waveform Display: Backlit, 10.1" high-resolution color LCD.
  • Digital Sampling Rate:
    • Pacemaker Spike Detection: 40,000 samples/second/channel.
    • Recording and Analysis: 1,000 samples/second/channel.
  • Paper: Perforated Z-fold thermal paper, A4 or 8.5" x 11" wide, 250 sheets.
  • Thermal Printer: Computer-controlled dot array; 1 dot/ms horizontal, 8 dots/mm vertical.
  • Thermal Printer Speeds: 5, 10, 25, or 50 mm/s.
  • Power Requirements: Universal AC power supply (110 - 240 VAC at 50/60 Hz) 110 VA; internal rechargeable battery.
  • Shipping Weight: 22.9 lb (10.4 kg).
  • Shipping Dimensions: 7.8" x 23.6" x 20.4" (19.9 cm x 60 cm x 51.7 cm).

Configurations

Baxter ELI 280 Resting Electrocardiograph Configurations

  • #BUR280-C1X: AM12 Wired Acquisition Module; LAN + USB.
  • #BUR280-81X: AM12 Wired Acquisition Module; LAN + WLAN + USB.
  • #BUR280-W1X: WAM Wireless Acquisition Module; LAN + WLAN + USB.
  • #ELI280-CAA-AAFBD: WAM Wireless Acquisition Module; LAN + WLAN + USB; DICOM.
  • #ELI280-AAA-AAFBD: AM12 Wired Acquisition Module; LAN + WLAN + USB; DICOM.
  • #ELI280-AAA-AAFBT: AM12 Wired Acquisition Module; LAN + WLAN + USB; DICOM, Security.
  • #ELI280-CAA-AAFBT: WAM Wireless Acquisition Module; LAN + WLAN + USB; DICOM, Security.

Frequently asked questions

Does the ELI 280 provide accurate ECG interpretation?

Yes, the ELI 280 features the highly reliable VERITAS Resting ECG Interpretation Algorithm. This advanced algorithm provides a comprehensive analysis by utilizing specific criteria:

  • It employs gender-specific, adult, and pediatric criteria for accurate analysis across different patient populations.
  • It offers a “silent second option” for interpretation.
  • It includes hook-up confirmation, which actively detects lead reversals to ensure the integrity of the collected data.
Does the ECG offer seamless EHR integration?

The Baxter ELI 280 is specifically engineered for high-volume clinical settings, providing robust connectivity to optimize your data management workflow.

Key integration features include:

  • Bidirectional Communication: Facilitates easy, two-way communication with existing Electronic Health Record (EHR) and Hospital Information Systems (HIS) to streamline charting and data retrieval.
  • Flexible Data Output: Reports are generated as standard PDF files. The device supports data transmission via the included LAN connection or an optional WiFi (WLAN) connection for enhanced portability.
  • Onboard Storage: The device has internal storage capacity for up to 200 ECGs.
  • Advanced Configurations: Depending on the selected configuration, the system can support specialized features such as DICOM communication protocols and advanced security functions.
How does the 'Best 10' feature improve ECG efficiency?

The Best 10 Feature is designed to significantly improve workflow efficiency, particularly in high-volume settings. It works by:

  • Automatically selecting and displaying the best 10 seconds of recorded ECG data from the device’s memory.
  • Reducing the need for repeat ECGs that typically occur due to patient movement or artifacts.

This intelligent selection ensures that clinicians have the highest quality trace for diagnosis without the time waste associated with retesting.

What is included to start testing immediately?

The Baxter ELI 280 comes as a complete, factory new package, providing everything necessary to begin high-quality 12-lead ECG acquisition immediately upon setup. The system includes:

  • The ELI 280 Instrument with current software
  • AHA 10-Wire, 12-Lead Lead Set (with banana plugs)
  • ECG Clip Adapters (set of 10)
  • A starter pouch of CardioSens Ultra II resting tab electrodes (100 electrodes)
  • A starter pack of 8.5” x 11” Letter Paper (perforated Z-fold thermal paper)
  • US/Canada Power Cord
Is the ELI 280 available with a wireless acquisition module?

Yes, the ELI 280 is designed for versatility and supports both wired and optional wireless acquisition methods. You can configure the system with the Optional Wireless Acquisition Module (WAM).

Key benefits of utilizing the WAM include:

  • Enhanced Mobility: It provides freedom of movement for clinicians and patients during acquisition, eliminating the restriction of a tethered cable.
  • Minimized Artifacts: By decoupling the acquisition module, it helps reduce cable-related and motion artifacts, leading to cleaner, more reliable ECG data.
  • Diagnostic Quality: The WAM maintains a full diagnostic-quality acquisition, featuring an ultra-high digital sampling rate of 40,000 samples/second/channel for accurate pacemaker spike detection.

The system can also be configured with the standard AM12 Wired Acquisition Module.

Is the ELI 280 easy to transport between rooms?

Yes, the Baxter ELI 280 is designed for portability and use in high-volume clinical environments. Its compact, low-profile design (15.5” x 17” x 4”) allows it to be easily placed on a desk or mounted on a mobile clinical cart.

Key features supporting mobility include:

  • Internal Rechargeable Battery: The unit includes an internal battery in addition to universal AC power, allowing for operation without constant access to a wall outlet.
  • Wireless Acquisition: For maximum flexibility, the system offers an optional Wireless Acquisition Module (WAM). This removes the constraints of traditional wired cables, which can improve patient comfort and reduce signal artifacts during transit.
  • Efficient Workflow: Features like the “Best 10” automatic capture help ensure you get clear diagnostic data quickly, minimizing the time needed per patient.
Does the ELI 280 feature a high-resolution color display?

Yes, the Baxter ELI 280 is equipped with a large, 10.1-inch high-resolution color LCD touchscreen designed to optimize clinical workflow and provide clear data visualization. Its features are tailored for efficiency:

  • Comprehensive View: The display utilizes a widescreen layout to show up to 12 leads of ECG data simultaneously.
  • User-Friendly Interface: The touchscreen facilitates easy menu navigation and rapid entry of patient demographics.
  • Quality Check: It allows for clear visual verification of proper electrode placement, which is essential for accurate data capture and reducing reprocessing time.
What is the internal ECG storage capacity?

The Baxter ELI 280 is designed for high-volume clinical settings and provides ample internal storage for patient records. The device can store up to 200 resting ECGs directly on the unit, allowing for convenient access and review of recent patient data.

Is the ELI 280 compatible with Z-fold thermal paper?

Yes, the ELI 280 is designed for high-volume environments and uses perforated Z-fold thermal paper to facilitate efficient reporting and handling.

The key printing specifications are:

  • Printer Type: Computer-controlled dot array thermal printer.
  • Paper Type: Perforated Z-fold thermal paper.
  • Capacity: Holds up to 250 sheets internally.
  • Supported Sizes: A4 or 8.5” x 11” wide.
  • Print Speeds: User-selectable speeds of 5, 10, 25, or 50 mm/s.
Does the ELI 280 support all patient age groups?

Yes, the Baxter ELI 280 is equipped to handle a wide spectrum of patient populations, including pediatric and adult cases. This broad support is driven by the sophisticated VERITAS Resting ECG Interpretation Algorithm. It provides accurate interpretation using:

  • Gender-specific criteria
  • Adult criteria
  • Pediatric criteria

This ensures that the ECG analysis is reliable and tailored for diverse patient demographics.