Sale price$48.66
Select a Configuration

Special Order Item

Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The B. Braun Perifix Filter and PinPad (25/Case) is available as a catheter filter and PinPad securement device for continuous epidural and PNB. When used together in conjunction, the Perifix Epidural Filter and Perifix PinPad reduce access errors and minimize complications resulting in safe and reliable epidural procedures.

Features

B. Braun Perifix Filter and PinPad Features

  • Not made with natural rubber.
  • 60 Month shelf life.

Epidural Filter Design:

  • 0.2 μm particulate filter.
  • Low profile design for patient comfort.

PinPad Design:

  • Helps reduce disconnects and access errors.
  • Allows patients to move freely while keeping the catheter connector and filter securely in place.

Configurations

B. Braun Perifix Filter and PinPad Configurations

MPN Configuration BPA Information DEHP Information PVC Information Dimensions per Case Shipping Weight per Case Sterile
#415004 PERIFIX PinPad - Securement Device for PERIFIX 0.2 µm Flat Epidural Filter N/A N/A N/A 7.320 x 6.320 x 5.640 inches 0.551 lb No
#415000 PERIFIX 0.2 µm Flat Epidural Filter - for use with all PERIFIX Catheters and PERIFIX PinPad Not made with BPA Not made with DEHP Not made with PVC 8.820 x 7.320 x 6.140 inches 0.661 lb Yes

Literature

Frequently asked questions

What are the clinical uses for the Perifix system?

The B. Braun Perifix Filter and PinPad system is designed for enhanced safety and integrity during continuous regional anesthesia procedures. It is specifically engineered to reduce access errors and minimize potential complications during administration.

The primary clinical applications are:

  • Continuous Epidural Procedures: Used for continuous administration while reducing associated complications.
  • Peripheral Nerve Block (PNB) Procedures: Provides a secure and filtered line management solution for ongoing infusions.

This system ensures procedural reliability through its two main components: a 0.2 μm particulate filter for fluid cleanliness, and the Perifix PinPad securement device that stabilizes the catheter connector, reduces accidental disconnects, and supports patient mobility.

Is the epidural filter 0.2 µm?

Yes, the B. Braun Perifix system utilizes a highly precise filter designed to enhance procedural safety and reliability.

  • Filter Size: The system incorporates a 0.2 µm particulate filter.
  • Purpose: This level of filtration is intended to minimize complications during continuous epidural and peripheral nerve block (PNB) procedures.
  • Design: The filter is constructed with a low profile to ensure better patient comfort during placement and ongoing use.
Is this device free of natural rubber?

Yes, the B. Braun Perifix Filter and PinPad is not made with natural rubber. This makes the device suitable for patients with latex sensitivities.

Does the B. Braun Perifix Filter and PinPad offer an extended shelf life?

Yes, the B. Braun Perifix Filter and PinPad offers an extended 60-month shelf life. This ensures long-term usability and helps minimize waste in medical facilities.

Does the PinPad securement device enhance safety?

Yes, the B. Braun Perifix PinPad is specifically designed to enhance the safety and reliability of continuous epidural and peripheral nerve block (PNB) procedures. It works by securely anchoring the catheter connector and the low-profile 0.2 µm filter to the patient, providing multiple critical benefits:

  • Reduces Complications: It is engineered to minimize the risk of accidental disconnects and reduce potential procedural access errors.
  • Maintains Stability: By stabilizing the connection, it protects the integrity of the system during continuous administration.
  • Supports Mobility: The PinPad secures the connection while allowing the patient to move freely, maximizing comfort without compromising the stability of the epidural line.
Are the PinPad and filter sold separately?

Yes, while the B. Braun Perifix system is designed for combined use to enhance procedural safety and reduce access errors, the PinPad securement device and the 0.2 µm Flat Epidural Filter are available for purchase as separate configurations.

Both configurations are supplied in cases of 25 units.

Component Features:

  • PERIFIX 0.2 µm Flat Epidural Filter: This component features a precise 0.2 μm particulate filter and a low-profile design, which helps maximize patient comfort during continuous epidural procedures. It is designed for use with all PERIFIX Catheters.
  • PERIFIX PinPad Securement Device: This device is engineered to securely hold the catheter connector and filter assembly. Its primary benefit is reducing the risk of accidental disconnects and allowing patients to move more freely while maintaining the stability of the epidural connection.
Is the system free of harmful materials?

Yes, the B. Braun Perifix system prioritizes patient safety by ensuring key components are free from common sensitizing and harmful materials.

  • Natural Rubber/Latex-Free: The entire Perifix system is explicitly not made with natural rubber, helping to minimize the risk of latex allergies.
  • Chemical-Free Components (Filter): The PERIFIX 0.2 µm Flat Epidural Filter component (SKU BBN-415000) is specifically manufactured without common chemicals of concern, including:
    • Bisphenol A (BPA)
    • Di-ethylhexyl phthalate (DEHP)
    • Polyvinyl chloride (PVC)
Does the design allow for patient comfort and mobility?

Yes, the B. Braun Perifix system is specifically engineered with features that prioritize both procedural security and patient comfort during continuous epidural and Peripheral Nerve Block (PNB) applications.Key design elements that enhance comfort and mobility include:* Low-Profile Filter Design: The PERIFIX 0.2 5m Flat Epidural Filter features a low profile, minimizing bulkiness and maximizing comfort for the patient during prolonged use.* Securement for Movement: The PinPad securement device securely anchors the catheter connector and filter. This stability allows patients to move more freely while significantly reducing the risk of accidental disconnects or procedural errors.* Material Safety: The product is explicitly designed without several common irritants. It is not made with natural rubber. Furthermore, the Filter variant is guaranteed to be free of BPA, DEHP, and PVC.

How many units are included in each case?

Each case contains 25 units of the selected B. Braun Perifix component.

This quantity applies consistently to both available configurations:

  • PERIFIX 0.2 µm Flat Epidural Filter (25 filters per case)
  • PERIFIX PinPad (25 securement devices per case)
Does the Perifix PinPad ensure secure catheter connections?

Yes, the B. Braun Perifix PinPad is specifically engineered to ensure secure and reliable catheter connections for continuous epidural and PNB procedures.

Its design focuses on enhancing procedural safety and supporting patient mobility:

  • Secure Anchorage: The PinPad firmly secures both the catheter connector and the associated 0.2 μm filter, which significantly reduces accidental disconnects and minimizes the potential for procedural access errors.
  • Patient Movement: By providing a stable anchor point, the PinPad allows patients to maintain relative freedom of movement without compromising the integrity or stability of the catheter line.
  • Enhanced Comfort: The low-profile design of the integrated 0.2 μm filter further contributes to patient comfort when secured by the PinPad.