B. Braun Introcan Safety Winged IV Catheters (200/Case) incorporate innovative Double Flashback technology which separates needle and catheter flashback to increase the likelihood of successful placement every time. Featuring a preferred passive safety design with built-in securement, each catheter is protected by a truly passive safety device that is activated automatically and cannot be by-passed. In fact, no extra steps are required to ensure healthcare worker and patient safety.

Each needle is extremely sharp and features Universal Bevel geometry to provide a wider choice of insertion angles that make the catheter easy to adapt to and venipuncture more comfortable for patients. And, thanks to using less plastic content than other safety IV catheters, Introcan Safety Winged IV Catheters are environmentally friendly.

Features

B. Braun Introcan Safety Winged IV Catheter Features

  • Preferred passive safety design with built-in securement.
  • Incorporates Double Flashback technology, or separate needle and catheter flashback, to increase the chances of successful placement every time.
  • Sharp needles boast Universal Bevel geometry for a wider choice of insertion angles.
  • Reduces the potential for needlestick injuries.
  • Promotes first stick success.
  • Improve patient comfort.
  • Environmentally friendly.

Specifications

B. Braun Introcan Safety Winged IV Catheter Specifications

SKU
Total Shelf Life
Ordering Unit
Units per Case
Dimensions per Case
Shipping Weight per Case
#4253566-02 60 Months Case 200 20.079" x 5.512" x 5.906" 2.425 lb
#4253574-02 60 Months Case 200 20.079" x 5.512" x 5.906" 2.425 lb
#4254538-02 60 Months Case 200 20.079" x 5.512" x 5.906" 2.425 lb
#4254570-02 60 Months Case 200 20.079" x 5.512" x 6.693" 3.086 lb
#4254597-02 60 Months Case 200 20.079" x 5.512" x 6.693" 3.086 lb
#4254503-02 60 Months Case 200 20.079" x 5.512" x 5.906" 1.984 lb
#4254511-02 60 Months Case 200 20.079" x 5.512" x 5.906" 1.984 lb
#4254546-02 60 Months Case 200 20.079" x 5.512" x 5.906" 2.425 lb
#4254562-02 60 Months Case 200 20.079" x 5.512" x 5.906" 2.866 lb
#4253540-02 60 Months Case 200 20.079" x 5.512" x 5.906" 1.984 lb
#4253590-02 60 Months Case 200 20.079" x 5.512" x 6.693" 3.086 lb
#4253604-02 60 Months Case 200 20.079" x 5.512" x 5.906" 2.866 lb
#4253612-02 60 Months Case 200 20.079" x 5.512" x 6.693" 3.086 lb
#4254512-02 60 Months Case 200 20.079" x 5.512" x 5.906" 1.984 lb
#4253523-02 60 Months Case 200 20.079" x 5.512" x 5.906" 1.984 lb
#4251609-02 60 Months Case 200 20.079" x 5.512" x 5.906" 2.866 lb
#4253511-02 60 Months Case 200 20.079" x 5.512" x 5.906" 1.984 lb
#4251614-02 60 Months Case 200 20.079" x 5.512" x 5.906" 2.646 lb
  • DEHP Information: Not made with DEHP.
  • Latex Information: Not made with natural rubber.
  • PVC Information: Not made with PVC.
  • Sterile: Yes.
  • Sterilization Method: EO.

Configurations

B. Braun Introcan Safety Winged IV Catheter Configurations

  • #4253566-02: 20 Ga x 1.25 in, PUR.
  • #4253574-02: 20 Ga x 1 in, PUR.
  • #4254538-02: 20 Ga x 1.25 in, FEP.
  • #4254570-02: 16 Ga x 2 in, FEP.
  • #4254597-02: 14 Ga x 2 in, FEP.
  • #4254503-02: 24 Ga x 0.75 in, FEP.
  • #4254511-02: 22 Ga x 1 in, FEP.
  • #4254546-02: 20 Ga x 1 in, FEP.
  • #4254562-02: 18 Ga x 1.25 in, FEP.
  • #4253540-02: 22 Ga x 1 in, PUR.
  • #4253590-02: 18 Ga x 1.75 in, PUR.
  • #4253604-02: 18 Ga x 1.25 in, PUR.
  • #4253612-02: 16 Ga x 2 in, PUR.
  • #4254512-02: 24 Ga x 0.55 in, FEP, Notched.
  • #4253523-02: 24 Ga x 0.75 in, PUR.
  • #4251609-02: 24 Ga x 0.55 in, FEP, Thinwall.
  • #4253511-02: 24 Ga x 0.55 in, PUR, Notched.
  • #4251614-02: 24 Ga x 0.55 in, PUR, Thinwall.