Condition:
-
Warranty:
- Weight: 1.1 lb
- Reaches a suction rate up to 760 mm Hg
- Available in both United States and International Models
-
Learn more:
-
MFR:
Allied Healthcare
Ships from MFI Medical
-
MPN: 22-14-0100
- Phone: (800) 444-3954
+Free Shipping*
Shop with Confidence
Free Shipping
Free Returns
Sales Tax Exemption
+Dedicated Account Managers
Frequently asked questions
Does the Vacutron High Vacuum Suction Regulator ensure stable vacuum settings?
Yes, absolutely. The Vacutron High Vacuum Suction Regulator features a dedicated Regulated operational mode that utilizes an internal mechanism to maintain stable, constant vacuum settings.
This mode allows for precise adjustment and reliable maintenance of pressure within the range of 0 to 760 mm Hg, ensuring consistent performance throughout critical medical procedures.
What operational modes are included?
The Allied Healthcare Vacutron Regulator features three critical operational modes, providing excellent control and versatility for various high-vacuum procedures:
- Regulated (REG): This mode provides precise and stable vacuum control, allowing you to set the pressure anywhere from 0 to 760 mm Hg. This is ideal for maintaining a constant vacuum setting.
- Full Line (FULL): This mode bypasses the regulator and delivers the maximum, unregulated vacuum pressure available directly from your central vacuum line source.
- OFF: This mode completely shuts off the vacuum flow to the patient line.
Are collection canisters included with the regulator?
No, the Allied Healthcare Vacutron High Vacuum Suction Regulator includes only the main regulator unit and the necessary wall and patient fittings based on your selected configuration.
Collection canisters and other fluid management accessories are sold separately to complete your suction setup. You will typically need to acquire:
- Disposable Collection Canisters
- Collection Canister Carrier or Holder
- Specimen Bags
- Critical Measurement Inserts
Is this regulator compatible with various wall fittings?
Yes, the Allied Healthcare Vacutron is engineered for versatility and is available in a wide array of configurations to ensure compatibility with different hospital wall fittings and patient outlets.
Key points regarding connectivity include:
- Extensive Compatibility: The unit is available in various United States and International models, allowing you to select the version that matches your facility’s specific wall inlet requirements (such as DISS, Ohmeda Diamond, or Chemetron quick-connect styles).
- Configurable Design: Depending on the selected model, the regulator features specific inlet and outlet fittings to ensure a secure, clinical-grade connection for your suction system.
When ordering, please ensure you select the configuration that matches the wall fitting standards used in your clinical environment.
What is included with the suction regulator?
The primary component included is the Allied Healthcare Vacutron High Vacuum Suction Regulator main unit, which is delivered Factory New and is covered by a generous 10-year warranty.
Included with the Regulator:
- The main suction regulator unit itself.
- The specific inlet and outlet fittings corresponding to the configuration you select (e.g., DISS Male, NPT, various quick-connect styles).
Accessories Purchased Separately:
Please note that essential accessories needed to operate a complete suction setup are not included with the unit and must be purchased separately. These typically include:
- Disposable Collection Canisters
- Collection Canister Carrier
- Canister Holder
- Specimen Bag
- Critical Measurement Insert
Does this device provide consistent suction performance?
Yes. The Vacutron is engineered with a precision internal regulation mechanism specifically designed to maintain stability. Once you select your desired vacuum setting, the device ensures that pressure remains consistent throughout the entire duration of the procedure.
What is the maximum regulated vacuum pressure?
The Allied Healthcare Vacutron regulator is a high-performance device capable of achieving a maximum regulated vacuum pressure of 760 mm Hg.
This high capacity allows for highly controlled and stable suction across the entire regulated range of 0 to 760 mm Hg, suitable for demanding clinical procedures.
For enhanced versatility, the regulator features three distinct operational settings:
- Regulated (REG): Maintains a constant, user-set vacuum pressure (0–760 mm Hg).
- Full Line (FULL): Delivers the maximum unregulated vacuum pressure available directly from the wall source.
- OFF: Shuts off the vacuum flow.
Precision is ensured by a vacuum gauge that displays measurements clearly in both mm Hg (up to 760) and kPa (up to 100).
What procedures is this regulator best for?
The Allied Healthcare Vacutron High Vacuum Suction Regulator is ideal for medical procedures that require a high, continuous suction rate up to 760 mm Hg. Its stable vacuum settings and two operational modes (regulated and full line) make it versatile for applications needing precise and powerful suction.
What units does the precise vacuum gauge display?
The Vacutron High Vacuum Suction Regulator uses a clear, dual-scale vacuum gauge to ensure precise and versatile pressure monitoring. The vacuum levels are displayed in two common clinical units:
- Millimeters of Mercury (mm Hg): The scale ranges from 0 to 760 mm Hg, with increments every 20 mm Hg.
- Kilopascals (kPa): The scale ranges from 0 to 100 kPa, with increments every 5 kPa.
This dual display capability aids in precise setting and monitoring according to various clinical requirements.
What are the physical dimensions of the unit?
The Allied Healthcare Vacutron High Vacuum Suction Regulator is designed with a compact, clinical footprint to ensure it fits easily into various medical care environments. Its physical dimensions are 6.8” (H) x 2.65” (W) x 4.07” (D), or 17.3 cm x 6.7 cm x 10.4 cm.
Allied Healthcare Vacutron High Vacuu...