Sale price$4,550.00
Select a Model

Item Discontinued

Description

The Allied Healthcare Timeter Aridyne 2000 Medical Air Compressor is a convenient bedside air compressor system that is both mobile and can replace a piped medical air system. A circuit breaker, elapsed time indicator, and thermal overload protector are also included.

Warranty: 1 Year - Free from Material Defects in Material and Workmanship.

The Timeter Aridyne 2000 is one of the quietest air compressors available, thanks to a unique design that keeps the internal chambers and pumps suspended for less noise. It's a hospital-grade system that can be utilized in the home or hospital for drawing and filtering ambient air for patient needs. The air is transferred through DISS air check valves at a pressure of 50 psi, with flow rates available up to and over 42 lpm. When air is taken in, it's compressed to 80 psi and sent through cooling coils to condense the moisture. The condensation is trapped and drained away automatically, and the air that's left is raised to 50 psi to be delivered out to other attached medical devices.

The Aridyne 2000 has both visual and audible alarm systems that alert users to high temperatures or low pressure changes in the system. The air compressor can also be used continuously for 24 hours a day, 7 days a week.

Features

Allied Healthcare Timeter Aridyne 2000 Medical Air Compressor Features

  • Automatically removes moisture from compressed air via the internal condensation trap.
  • Air pump filter cleans air and maintains quiet operation.
  • Contains audio and visual alarms in case of high temperature changes or low pressure.
  • Three DISS medical air outlets.

Specifications

Allied Healthcare Timeter Aridyne 2000 Medical Air Compressor Specifications

  • Continuous Flow: 56 lpm.
  • Pressure: 50 psi.
  • Dimensions: 17" (W) x 21.5" (D) x 34.5" (H) (43.2 cm x 54.6 cm x 87.6 cm).

Configurations

Allied Healthcare Timeter Aridyne 2000 Medical Air Compressor Configurations

  • #TE20: 115 V / 60 Hz [157 lb (71.2 kg)].
  • #TE69: 220 V / 50 Hz [161 lb (72.6 kg)].
  • #T11604: 230 V / 60 Hz [161 lb (72.6 kg)].

Accessories

Allied Healthcare Timeter Aridyne 2000 Medical Air Compressor Accessories

The Timeter Aridyne 2000 Medical Air Compressor is typically purchased with the following items. Please note that these are NOT included with the Timeter Aridyne 2000. They are sold separately.

  • #T901-405: Replacement Intake Air Filter - Foam.
  • #12-80-3011: Oxygen Check Valve Outlet (DISS male and 1/8" NPT female).
  • #12-80-3111: Air Check Valve Outlet (DISS Male and 1/8" NPT female).

Replacement Parts

The following are replacement parts for worn or broken components of the Aridyne 2000 system. These parts are sold separately.

  • #TZ104: Allied Healthcare Timeter Aridyne 2000 Preventive Maintenance Kit.
  • #T648-301: Allied Healthcare Timeter Aridyne 2000 Replacement Air Deflector.
  • #T12149: Allied Healthcare Timeter Aridyne 2000 Replacement Blower Assembly.
  • #T11286: Allied Healthcare Timeter Aridyne 2000 Replacement Bulkhead Adapter Assembly.
  • #T12001: Allied Healthcare Timeter Aridyne 2000 Replacement Compressor Overhaul Kit.
  • #T990-411: Allied Healthcare Timeter Aridyne 2000 Replacement Cylinder.
  • #T990-427: Allied Healthcare Timeter Aridyne 2000 Replacement Fan Blade.
  • #T990-428: Allied Healthcare Timeter Aridyne 2000 Replacement Fan Shroud.
  • #T990-431: Allied Healthcare Timeter Aridyne 2000 Replacement Piston and Rod Assembly.
  • #T510-502: Allied Healthcare Timeter Aridyne 2000 Replacement Power Switch.
  • #T12156: Allied Healthcare Timeter Aridyne 2000 Replacement Pressure Gauge.
  • #T990-434: Allied Healthcare Timeter Aridyne 2000 Replacement Pressure Relief Valve.
  • #T580-501: Allied Healthcare Timeter Aridyne 2000 Replacement Pressure Switch.
  • #T12152: Allied Healthcare Timeter Aridyne 2000 Replacement Pump Inlet Filter Assembly.
  • #T613-005: Allied Healthcare Timeter Aridyne 2000 Replacement Shipping Carton.
  • #T026-116: Allied Healthcare Timeter Aridyne 2000 Replacement Splash Shield.
  • #T611-309: Allied Healthcare Timeter Aridyne 2000 Replacement Suspension Spring.
  • #T586-501: Allied Healthcare Timeter Aridyne 2000 Replacement Thermostat.
  • #T8134: Allied Healthcare Timeter Aridyne 2000 Replacement Time Elapsed Indicator.
  • #T028-118: Allied HealthcareTimeter Aridyne 2000 Replacement Compressor with Suspension.
  • #T326-201: Allied Healthcare Timeter Aridyne 2000 Replacement DC, 6-Volt Battery.
  • Allied Healthcare Timeter Aridyne 2000 Replacement Sealing Sleeve.

Literature

Allied Healthcare Timeter Aridyne 2000 Medical Air Compressor Literature

Allied Healthcare Timeter Aridyne Medical Air Compressor Brochure

Frequently asked questions

Is this a new product?

Yes, it’s a factory new product from Allied Healthcare, ensuring you receive a brand-new unit with full functionality.

Is it suitable for continuous use?

Yes, the compressor is designed for 24/7 continuous operation, making it highly reliable for ongoing medical needs.

Does it efficiently remove moisture?

Yes, the Allied Healthcare Timeter Aridyne 2000 Medical Air Compressor features an internal condensation trap that automatically removes moisture from compressed air, ensuring clean air delivery. The air is compressed, then cooled to condense moisture, and finally automatically drained.

Does it have a reliable alarm system?

The system features both audio and visual alarms that activate in case of high temperature or low pressure, alerting users to potential issues.

Is the operation truly quiet?

It is designed with a unique system that suspends internal chambers and pumps, significantly reducing operational noise for a quieter environment.

Is the compressor easily mobile?

Yes, the Allied Healthcare Timeter Aridyne 2000 Medical Air Compressor is designed for easy mobility, making it suitable for bedside use and flexible deployment. It is equipped with four black wheels for convenient transport within healthcare facilities or home settings.

What are the maximum pressure and flow outputs?

The Allied Healthcare Timeter Aridyne 2000 is a high-performance, hospital-grade medical air compressor designed for continuous (24/7) operation.

Its primary output specifications are:

  • Delivery Pressure: The regulated output pressure is a consistent 50 psi. (The system compresses air internally to 80 psi before regulation.)
  • Continuous Flow Rate: The unit is specified for a continuous flow rate of 56 liters per minute (lpm).
  • Maximum Flow Rate: The advertised maximum flow rate is over 42 lpm.
  • Outlets: Output is delivered via three DISS medical air outlets.
Does it have multiple air outlets?

Yes, the Allied Healthcare Timeter Aridyne 2000 Medical Air Compressor is equipped with three DISS medical air outlets, allowing for the connection of multiple devices to meet patient air needs.

How is the compressed air filtered and dried?

The Allied Healthcare Timeter Aridyne 2000 utilizes a robust, integrated system to ensure the delivered medical air is filtered and dry:

  • Intake Filtration: Ambient air is first drawn into the unit and cleaned by an internal air pump filter to remove particulates.
  • Automatic Moisture Removal (Drying): After compression, the air passes through cooling coils, which causes moisture to condense. This condensation is collected in an internal condensation trap and is automatically drained from the system.

This continuous process provides clean, conditioned air suitable for patient needs.

Does this air compressor feature safety alarms?

Yes, the Timeter Aridyne 2000 includes robust monitoring and safety features essential for reliable, continuous operation.Key safety components are:

  • Audio and Visual Alarms: Alerts users immediately upon detecting:
    • High temperature changes
    • Low pressure fluctuations
  • Internal Protection: The unit is safeguarded by an integrated circuit breaker and a thermal overload protector.
  • Monitoring: An elapsed time indicator tracks total operational hours, which is vital for scheduled preventive maintenance.