Regular price$2,380.00 Sale price$1,999.18
Select a Configuration

2+ In Stock

Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Welch Allyn Spot Vital Signs 4400 Device includes one adult blood pressure cuff.

Warranty: 2 Years.

The Welch Allyn Spot Vital Signs 4400 Device offers an efficient way to capture, access, and document patient vitals, including temperature and blood pressure averaging, so that you can focus on spending more time with your patients.

Its intuitive, all-in-one design makes the Spot Vital Signs Device easy to use for caregivers at any level. Add it to your existing workflow without disruption and begin exams quickly from the touchscreen.

Blood pressure averaging can help you diagnose high blood pressure by improving accuracy and reducing errors, while mitigating the impact of factors like White Coat Effect.

Features

Welch Allyn Spot Vital Signs 4400 Device Features

  • Lightweight and portable with a variety of mounting options.
  • All configurations include NIBP, pulse rate, and MAP.
  • Measures NIBP, pulse rate, temperature, and SpO2 in about 30 seconds.
  • Portable design can help standardize vitals capture throughout your facility and increase productivity for high-volume environments.
  • Save time and help reduce data entry errors by sending patient data to the EMR.
  • Blood pressure averaging helps provide a more accurate view of your patient's heart health, so you can detect hypertension with confidence.
  • 8-hour Lithium ion battery to maximize time before recharging.

Specifications

Welch Allyn Spot Vital Signs 4400 Device Specifications

  • Electrical Rating: 100 to 240 V AC, 50 to 60 Hz, 0.8 A to 0.5 A.
  • Dimensions: 10.1" x 9.3" x 4.9" (25.7 cm x 23.6 cm x 12.4 cm).
  • Weight (Including Battery): 3.8 lb (1.7 kg).
  • 2-Cell Battery Usage: Up to 8 hours of operation.
  • Display Active Area: 6.1" x 3.4" (154.1 mm x 85.9 mm).
  • Display Resolution: 800 x 480 pixels.
  • Environmental Conditions:
    • Operating Temperature: 50 degrees F to 104 degrees F (10 degrees C to 40 degrees C).
    • Storage/Transport Temperature: -4 degrees F to 122 degrees F (-20 degrees C to 50 degrees C).
    • Operating Humidity: 15% to 90% Non-Condensing.
    • Storage/Transport Humidity: 15% to 95% Non-Condensing.
  • NIBP:
    • Cuff Pressure Range: Meets or exceeds IEC/ISO 80601-2-30 Standard for Cuff Pressure Range.
    • Systolic Range:
      • Adult: 30 to 260 mmHg (StepBP, SureBP).
      • Pediatric: 30 to 260 mmHg (StepBP, SureBP).
    • Diastolic Range:
      • Adult: 20 to 220 mmHg (StepBP, SureBP).
      • Pediatric: 20 to 220 mmHg (StepBP, SureBP).
    • Cuff Inflation Target:
      • Adult: 160 mmHg (StepBP).
      • Pediatric: 140 mmHg (StepBP).
    • Maximum Target Pressure:
      • Adult: 280 mmHg (StepBP, SureBP).
      • Pediatric: 280 mmHg (StepBP, SureBP).
    • Blood Pressure Determination Time:
      • Typical: 15 seconds.
      • Maximum: 150 seconds.
    • Blood Pressure Accuracy: Meets or exceeds ISO 81060-2:2013 standards for NIBP (+/- 5 mmHg mean error, 8 mmHg standard deviation).
    • Mean Arterial Pressure (MAP) Range:
      • Adult: 23 to 230 mmHg (StepBP, SureBP).
      • Pediatric: 23 to 230 mmHg (StepBP, SureBP).
    • Pulse Rate Range (Using Blood Pressure Determination):
      • Adult: 30 to 200 bpm (StepBP, SureBP).
      • Pediatric: 30 to 200 bpm (StepBP, SureBP).
    • Pulse Rate Accuracy (Using Blood Pressure Determination): +/- 5% (+/- 3 bpm).
    • Overpressure Cutoff:
      • Adult: 300 mmHg +/- 15 mmHg.
      • Pediatric: 300 mmHg +/- 15 mmHg.
  • SureTemp Plus Temperature Range: 80 degrees F to 110 degrees F (26.7 degrees C to 43.3 degrees C).
  • SpO2:
    • SpO2 Performance Measurement Range: 1% to 100%.
    • Pulse Rate: 18 to 300 bpm +/- 3 digits; Low perfusion (40 to 240 bpm) +/- 3 digits.
    • Saturation: 70 to 100%.
  • Shipping Dimensions: 15" x 16" x 8" (38.1 cm x 40.6 cm x 20.3 cm).
  • Shipping Weight: 9 lb (4.1 kg).

Configurations

Welch Allyn Spot Vital Signs 4400 Device Configurations

  • #44XT-B: Spot 4400 with NIBP and SureTemp Thermometer.
  • #44WT-B: Spot 4400 with NIBP, SureTemp Thermometer, and Nonin SpO2.

Frequently asked questions

How quickly does it capture vital signs?

The Welch Allyn Spot Vital Signs 4400 is engineered for speed, capturing comprehensive vital signs typically in just 30 seconds. This rapid measurement time enhances caregiver efficiency.

The device measures the following key parameters:

  • Non-Invasive Blood Pressure (NIBP) and Mean Arterial Pressure (MAP)
  • Pulse Rate
  • SureTemp Plus Temperature
  • SpO2 (Blood Oxygen Saturation, included with optional configurations)

A critical feature for diagnostic accuracy is blood pressure averaging, which helps provide a more reliable reading for hypertension assessment by mitigating factors like the White Coat Effect.

Does the device offer a long-lasting battery for clinical use?

Yes, the Welch Allyn Spot Vital Signs 4400 Device is engineered for high-volume environments and includes a reliable power system to ensure consistent operation throughout your shift.

  • Extended Runtime: The integrated Lithium-ion battery provides up to 8 hours of continuous operation on a single charge.
  • Mobile Efficiency: Combined with its lightweight design—weighing just 3.8 lbs (1.7 kg)—this long-lasting power source allows you to move freely between exam rooms without needing to tether the device to a power outlet.
  • Consistent Performance: The internal power management is designed to support the needs of busy clinics, helping you stay focused on patient care rather than battery levels.
Does this device offer EMR integration?

Yes, the Welch Allyn Spot Vital Signs 4400 Device fully supports Electronic Medical Record (EMR) integration.

This crucial feature is designed for workflow efficiency, allowing patient vital signs data to be transferred directly to the EMR system. This connectivity helps to:

  • Reduce Manual Errors: Minimizes the risk of transcription errors associated with manual data entry.
  • Save Time: Eliminates the need for manual documentation, allowing caregivers to maximize time spent on patient care.
  • Streamline Documentation: Ensures accurate and rapid standardization of data capture across the facility.
Is a high-quality adult blood pressure cuff included?

Yes, the Welch Allyn Spot Vital Signs 4400 Device is ready for immediate clinical use and includes one high-quality adult blood pressure cuff.

This device is engineered to ensure consistent and reliable measurements, with blood pressure accuracy that meets or exceeds the ISO 81060-2:2013 standards. The included cuff integrates seamlessly with the system to provide rapid, precise Non-Invasive Blood Pressure (NIBP) readings as part of the unit’s efficient multi-parameter monitoring capabilities.

Is the Spot 4400 highly portable?

Yes, the Welch Allyn Spot Vital Signs 4400 is specifically engineered for high portability and versatility, supporting use in high-volume clinical and mobile settings.

Key features that maximize its mobility and operational uptime include:

  • Lightweight Design: The device is highly compact and weighs only 3.8 lb (1.7 kg), including the integrated battery.
  • Long-Lasting Battery: It is powered by an 8-hour Lithium-ion battery, allowing for extended operational time before recharging is required.
  • Flexible Placement: The portable design makes it suitable for mobile patient assessments, and it also supports various mounting options for standardization across different facility departments.
Does this device provide high-precision NIBP readings?

Yes, the Welch Allyn Spot Vital Signs 4400 Device is engineered for high clinical accuracy, ensuring reliable vital sign measurements. It is particularly effective for hypertension detection due to several key features:

  • Blood Pressure Averaging: This feature helps neutralize external variables and reduces the impact of the ‘White Coat Effect,’ leading to more precise diagnostic results.
  • Rapid Assessment: The device captures blood pressure, pulse rate, temperature, and SpO2 (on select models) in approximately 30 seconds.
  • Clinical Efficiency: By standardizing the measurement process, it minimizes manual entry errors and allows for seamless integration into EMR systems.
Does blood pressure averaging enhance diagnostics?

Yes, the Welch Allyn Spot Vital Signs 4400 Device includes a crucial blood pressure averaging feature designed to improve the accuracy and confidence of Non-Invasive Blood Pressure (NIBP) measurements.

This function provides significant clinical value by:

  • Improving Diagnostic Accuracy: It delivers a more representative view of the patient’s cardiovascular status than a single reading.
  • Aiding Hypertension Detection: Supports clinicians in the confident detection and management of hypertension.
  • Mitigating the White Coat Effect: Reduces measurement variability caused by patient anxiety (the “White Coat Effect”), ensuring readings are not artificially inflated.
Does the device streamline clinical workflow?

Yes, the Welch Allyn Spot Vital Signs 4400 is specifically engineered for high-volume environments to maximize caregiver productivity and streamline clinical workflow.

Key features that enhance efficiency and integration include:

  • Rapid Vitals Capture: The device measures NIBP, pulse rate, and temperature (and optional SpO2) in approximately 30 seconds for rapid patient assessment.
  • EMR/EHR Connectivity: It can send patient data directly to your Electronic Medical Record (EMR/EHR) system, which saves time, eliminates manual transcription, and helps reduce data entry errors.
  • Intuitive Operation: The all-in-one design includes a responsive touchscreen interface, allowing caregivers at any skill level to quickly begin exams.
  • Portability and Power: It features a lightweight design and a powerful 8-hour Lithium-ion battery, ensuring maximized operational uptime and easy mobility throughout the facility.
Does the device support consistent and reliable monitoring?

Yes, the Welch Allyn Spot Vital Signs 4400 is built for clinical-grade reliability and high-volume use. It ensures dependable performance through several key features: <ul><li>Continuous Monitoring: Supports ongoing tracking of NIBP, pulse rate, and MAP.</li><li>ISO Certified: Meets or exceeds the strict ISO 81060-2:2013 standards for NIBP accuracy.</li><li>High-Confidence Diagnostics: Utilizes blood pressure averaging to mitigate the “White Coat Effect,” ensuring more representative patient readings.</li><li>Rugged Design: Housed in high-impact plastic, this device is engineered to withstand the daily demands of hospital and urgent care environments.</li></ul>

What are the electrical compatibility specifications?

The Welch Allyn Spot Vital Signs 4400 is designed for broad compatibility across various clinical settings, supporting a wide range of global power standards.

The AC electrical rating specifications are:

  • Voltage: 100 to 240 V AC
  • Frequency: 50 to 60 Hz
  • Current: 0.8 A to 0.5 A

For enhanced portability and continuous workflow, the device also includes an integrated 8-hour Lithium-ion battery to maximize operational uptime when AC power is not readily available.