Regular price$8,914.37 Sale price$6,881.08
Select a Color
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Allied Healthcare AHP300 Transport Ventilator is an electrically controlled, portable ventilator, designed to provide emergency respiratory support by means of a face mask or tube inserted into the patient's airway. It allows for invasive and non-invasive respiratory support with a variety of ventilation modes to choose from.

Note: Oxygen source is not included.

Warranty: 1 Year - Free from Manufacturing Defects (Unit and Battery).

The AHP300 Transport Ventilator is intended for use in EMS (emergency medical services) environments, inter-hospital transport, and hospital facilities, by qualified critical care nurses, paramedics, and respiratory therapists.

Features

Allied Healthcare AHP300 Transport Ventilator Features

  • Modes:
    • (Pressure or Volume) A/CMV.
    • (Pressure or Volume) SIMV.
    • CPAP.
    • Bi-Level Support (PS+CPAP) (can be programmed in custom mode).
    • NIV (non-invasive ventilation) available in all modes.
    • Five Programmable Quick Start Presets.
  • Monitored Parameters: Paw (Peak, Base), Delivered Tidal Volume, Spontaneous Breath Count, Integrated Battery Level, External Battery Level (when attached).
  • Calculated Parameters: I:E Ratio, Flow rate, and FiO2.
  • Quick Start Ventilation: The AHP300 features programmable presets, allowing trained caregivers to rapidly recall up to five saved ventilation protocols.
  • Long Battery Life: Up to 7.5 hours on internal battery, with auxiliary battery capability for up to 21 hours of battery life.
  • Oxygen Conserve Mode: Allows the use of low pressure sources (oxygen concentrator, liquid oxygen, etc.) to extend the available amount of oxygen.
  • Multi-Environment Capability: For everyday transport or evacuation from extreme environments. The AHP300 features rugged shock and vibration resistance as well as IPX22 water resistance.
  • Low Cost of Ownership: Simple preventive maintenance schedule along with low-cost battery and repair parts result in significant saving and lower cost of ownership than competitor's broad-featured ventilators.

Specifications

Allied Healthcare AHP300 Transport Ventilator Specifications

  • Patient Range: Infant/Pediatric (5 kg / 11 lb and up) to Adult.
  • Controls/Settings:
    • Tidal Volume: 40 to 2000 ml.
    • RR (Respiratory Rate): 0 or 5 to 60 b/min.
    • I Time (Inspiratory Time): 0.5 to 2.0 seconds.
    • PEEP/CPAP: 0 to 25 cmH2O / 0 to 25 mbar.
    • Flow: 5 to 60 L/min (flows > 80 LPM in PS Mode, CPAP and demand flows).
    • Pressure Control (Target Pressure): 15 to 55 cmH2O / 15 to 55 mbar.
    • Ptrig (Sensitivity): -5 to -2 cmH2O / -5 to -1 mbar.
    • Manual Inflation: 2 second maximum.
    • FiO2: 0.21 to 1.00.
    • Maximum I Time: 2 seconds.
    • Flow Wave Pattern: Square or descending (depending on mode selected).
    • Auto Lock Function: ON / OFF.
    • Remote Alarm Option: Normally Open/Closed.
  • Alarms:
    • High Airway Pressure: 10 to 55 cmH2O / 10 to 55 mbar.
    • Low Airway Pressure: 5 to 15 cmH2O / 5 to 15 mbar.
    • Back-Up Ventilation Alert: 20 seconds fixed, apnea ventilation mode.
    • Low Source O2: Triggers at 40 to 37 psi.
    • Low Source Air: Triggers at 40 to 37 psi.
    • Device Alert: Malfunction alert.
    • Critical Battery: Approximately 20 minutes of battery charge remains.
    • Silence/Reset: 110 seconds.
  • Pneumatics:
    • Gas Delivery System: Internal dual diaphragm.
    • Air/Oxygen Mixer: Integrated.
    • Oxygen Input: 41 to 87 psig oxygen.
  • Power Requirements:
    • AC Voltage: 110 to 240 VAC, 50/60 Hz, max. 1 A.
    • DC Voltage: 11 to 15 VDC, max. 5 A.
  • Integrated Battery Parameters:
    • Battery Composition: Sealed Lead Acid.
    • Run Time:
      • 100% O2: 7.5 hours.
      • 60% O2: 7.5 hours.
      • 100% Air (on compressor): 7 hours.
  • Dimensions: 13.3" (W) x 5.3" (D) x 13.8" (H) (34 cm x 13 cm x 35 cm).
  • Weight: 18.8 lb (8.5 kg).
  • Signal Connections:
    • Remote Alarm: 1/4" phone jack to connect to nurse call or remote system.
  • Environmental:
    • Shock: 100 G-Force.
    • Vibration: To IEC 60068-2-6.
    • Operating Temperature: 0 to 122 °F (-18 to 50 °C).
    • Storage Temperature: -40 to 140 °F (-40 to 60 °C).
    • Operating Humidity: 5 to 95% (non-condensing).
    • Water Ingress: IPx22.
  • Shipping Dimensions: 21" x 19" x 11".
  • Shipping Weight: 27.1 lb.

Colors

Allied Healthcare AHP300 Transport Ventilator Colors

  • #AHP300: White Casing.
  • #AHP300-Y: Yellow Casing.

Accessories

Allied Healthcare AHP300 Transport Ventilator Accessories

The following accessory items and consumables are recommended as most compatible with the AHP300 Transport Ventilator. They are sold separately.

  • #31-21-3271: Mechanical Test Lung.
  • Single Limb Patient Ventilator Circuit:
    • #L599-600: Adult (10/Case).
    • #L599-650: Pediatric (20/Case).
  • #64020: Bacterial Exhalation Filter (50/Case).
  • Disposable Cuffed Mask:
    • #L595161-10: Adult (10 per Bag).
    • #L595162-10: Child (10 per Bag).
  • #890113: Disposable Mask Restraint (12/Case).

Frequently asked questions

Can the AHP300 treat infants to adults?

Yes, the Allied Healthcare AHP300 Transport Ventilator is engineered to provide comprehensive respiratory support across a wide patient range.

It is suitable for:

  • Infant/Pediatric patients (starting at 5 kg / 11 lb and up)
  • Adult patients

This broad capability ensures the device is highly versatile for various emergency medical services (EMS) and critical care transport scenarios.

Does the ventilator offer extended battery runtime?

Yes, the Allied Healthcare AHP300 Transport Ventilator features robust battery options for extended operation during critical care transport:

  • Standard Internal Runtime: The integrated Sealed Lead Acid battery provides up to 7.5 hours of continuous run time (when operating with oxygen). If using the internal compressor with 100% air, the runtime is approximately 7 hours.
  • Maximum Extended Runtime: This operational time can be significantly increased up to 21 hours by connecting an optional auxiliary battery.

For effective power management, the ventilator actively monitors and displays the levels for both the internal battery and the external battery (when attached).

What ventilation modes are included?

The Allied Healthcare AHP300 is engineered for versatility, offering multiple modes that support both invasive and Non-Invasive Ventilation (NIV) delivery.

The included ventilation modes are:

  • (Pressure or Volume) A/CMV: Assist/Control Mandatory Ventilation
  • (Pressure or Volume) SIMV: Synchronized Intermittent Mandatory Ventilation
  • CPAP: Continuous Positive Airway Pressure
  • Bi-Level Support (PS+CPAP)
Is the AHP300 built for rugged transport environments?

Yes, the Allied Healthcare AHP300 is specifically engineered for high-stress transport scenarios, including EMS, inter-hospital transfers, and critical care environments. Its rugged construction ensures reliable performance under demanding conditions:

  • Shock Resistance: The unit is built to endure significant physical impact, featuring 100 G-force shock resistance.
  • Water Ingress Protection: It is rated IPX22, providing protection against water ingress during transit.
  • Reliable Durability: Designed to maintain consistent respiratory support in both invasive and non-invasive applications, even when moving through diverse and challenging medical transit environments.
Does the AHP300 feature rapid deployment presets?

Yes, the Allied Healthcare AHP300 is engineered for rapid deployment in critical situations.

It features five programmable Quick Start Presets that enable trained caregivers to instantly recall saved ventilation protocols, significantly speeding up intervention time during transport.

What are the key ventilation control ranges?

The Allied Healthcare AHP300 Transport Ventilator is highly versatile, designed to support a wide patient range from Infant/Pediatric (starting at 5 kg / 11 lb) to Adult. It offers precise control over essential respiratory parameters to meet critical care needs.

Key settings and their ranges are:

Setting Range
Tidal Volume 40 to 2000 ml
Respiratory Rate (RR) 0 or 5 to 60 breaths/min
PEEP/CPAP 0 to 25 cmH₂O / mbar
Pressure Control (Target Pressure) 15 to 55 cmH₂O / mbar
Inspiratory Time (I Time) 0.5 to 2.0 seconds
Sensitivity (Ptrig) -5 to -2 cmH₂O / mbar
FiO₂ (Oxygen) 0.21 (Room Air) to 1.00 (100% Oxygen)

Standard flow rates range from 5 to 60 L/min, with the device capable of achieving flows greater than 80 L/min in modes utilizing pressure support, CPAP, and demand flows.

What power requirements does this unit have?

The ventilator operates on both AC and DC power:

  • AC Power Requirements: 110 to 240 VAC, 50/60 Hz, max. 1 A.
  • DC Power Requirements: 11 to 15 VDC, max. 5 A.
What critical parameters does the AHP300 monitor?

The Allied Healthcare AHP300 Transport Ventilator monitors a comprehensive set of patient respiratory mechanics and device status indicators crucial for critical care transport.

Directly Monitored Parameters include:

  • Paw (Peak and Base Airway Pressure)
  • Delivered Tidal Volume
  • Spontaneous Breath Count
  • Integrated Battery Level
  • External Battery Level (when an auxiliary battery is attached)

The ventilator also provides Calculated Parameters:

  • I:E Ratio
  • Flow rate
  • FiO₂ (Fraction of Inspired Oxygen)
Does this ventilator feature a wide FiO₂ range?

Yes, the Allied Healthcare AHP300 Transport Ventilator includes an integrated Air/Oxygen Mixer to provide a wide and precise range for the Fraction of Inspired Oxygen (FiO₂).

This versatility allows medical professionals to deliver concentrations suitable for diverse patient requirements, spanning from ambient air levels up to 100% pure oxygen.

The adjustable FiO₂ setting range is 0.21 to 1.00.

What is the required oxygen input pressure range?

The Allied Healthcare AHP300 Transport Ventilator requires a source oxygen input pressure between 41 and 87 psig.

This pressurized input is necessary to operate the integrated Air/Oxygen Mixer within the unit.