Condition:
-
Warranty:
- Weight: 143.13 lb
- Incorporates optical focusing, instead of requiring you to move the colposcope body, for sharp images within a working distance of 220 to 350 mm
- Single-Handed Operation: Several different control knobs are gathered close together, so you can adjust the view field, zoom, or focus with just one hand using either a left or right grip
- Eyepiece Magnification: 10x
- The video system (optional) and light source can be used for Hysteroscopy
-
Learn more:
-
MFR:
Olympus
Ships from MFI Medical
- Phone: (800) 401-1086
+Shipping
Shop with Confidence
Sales Tax Exemption
+Dedicated Account Managers
Frequently asked questions
Does the OCS-500 have a wide focus range?
Does the OCS-500 support advanced digital documentation?
<p>To enable these capabilities, ensure you select the <strong>“With Video” configuration</strong>. This model includes a dedicated CCD camera and BNC cable to facilitate digital imaging. Key benefits include:</p>
<ul>
<li><strong>Seamless Integration:</strong> Designed to pair with compatible Olympus video systems, such as the OTV-S7V VISERA or OTV-SC series, for optimal performance.</li>
<li><strong>Direct Documentation:</strong> Supports the ability to print documentation directly via compatible digital color photo printers.</li>
<li><strong>Versatile Utility:</strong> Ideal for capturing and archiving images during both routine colposcopy and diagnostic hysteroscopy.</li>
</ul>
What is included in the standard colposcope package?
<p>Key components included in the standard package are:</p>
<ul>
<li><strong>Zoom Microscope Body:</strong> The core optical component, featuring non-step continuous zoom and adjustable focal length (220 mm to 350 mm).</li>
<li><strong>Illumination System:</strong> A <strong>Halogen light source</strong> along with the necessary fiber optic light cable.</li>
<li><strong>Stand Assembly:</strong> Includes the floor stand base, main stand, horizontal arm, and a spring-balanced <strong>balance arm</strong> designed for ergonomic, single-handed control.</li>
</ul>
<p>If you select the optional ‘With Video’ configuration, it additionally includes a <strong>CCD camera</strong> and a <strong>BNC cable</strong> for digital documentation capabilities.</p>
Is a detachable green filter included for contrast enhancement?
<p>This filter is crucial for gynecological examinations because it:</p>
<ul>
<li>Significantly enhances contrast.</li>
<li>Improves the visualization of blood vessels and tissue structure.</li>
</ul>
<p>The base unit utilizes a light guide connected to a <strong>Halogen light source</strong> and includes a fiber optic light cable. The system offers versatility and is compatible with other Olympus light sources, such as the <strong>CLV-S40/S45 VISERA Xenon Light Source</strong> and the <strong>CLH-SC Halogen Light Source</strong>.</p>
Is the OCS-500 Colposcope easy to maneuver and adjust?
<ul>
<li><strong>Intuitive Single-Handed Operation:</strong> Critical control knobs for zoom, focus, and field adjustment are conveniently grouped, allowing the user to operate these functions with a <strong>single hand</strong> (left or right grip).</li>
<li><strong>Optical Focusing:</strong> The system utilizes refined optical focusing (adjustable from 220 mm to 350 mm) to achieve sharp images, <strong>eliminating the need to move the entire colposcope body</strong> for focal adjustments.</li>
<li><strong>Fluid Movement:</strong> The unit is supported by a floor stand with a spring-balanced pantographic arm system, providing smooth maneuverability. The arm allows for <strong>270° rotation</strong> and 300 mm of vertical movement. The balance is easily adjusted via a handle to maintain stable positioning.</li>
</ul>
Does the Olympus OCS-500 support hysteroscopy?
<p>To utilize this feature, the system must be equipped with the <strong>optional video configuration</strong> (which includes a CCD camera and BNC cable) and a compatible light source. The conversion is performed quickly and easily using an eyepiece mount, allowing for comprehensive digital documentation of both types of procedures.</p>
Which Olympus camera and light sources are compatible?
<h3>Compatible Video and Camera Systems</h3>
<p>These systems allow for the high-resolution capture and digital storage of both colposcopic and hysteroscopic images:</p>
<ul>
<li><strong>Olympus OTV-S7V VISERA Endoscopic Camera System</strong></li>
<li><strong>Olympus OTV-SC Video Systems</strong></li>
</ul>
<h3>Compatible Light Sources</h3>
<p>Optimal illumination for detailed examinations is ensured using these external light sources:</p>
<ul>
<li><strong>CLV-S40/S45 VISERA Xenon Light Source</strong></li>
<li><strong>CLH-SC Halogen Light Source</strong></li>
</ul>
What is the variable magnification range?
<p>The total magnification ranges from <strong>2.7x up to 23.4x</strong>, depending on the working distance (WD):</p>
<ul>
<li><strong>Minimum Magnification (2.7x):</strong> Achieved at the maximum working distance of 350 mm.</li>
<li><strong>Maximum Magnification (23.4x):</strong> Achieved at the minimum working distance of 220 mm.</li>
</ul>
<p>The unit features optical focusing across the 220 mm to 350 mm working distance range, ensuring sharp images without the need to move the colposcope body.</p>

Olympus OCS-500 Colposcope