The Smiths Medical Medfusion 4000 (#MED-4000) comes pre-configured allowing for manual delivery modes and custom configurations so you can base dosage on minutes, hours, days, etc. This top-of-the-line syringe pump is specially designed to provide the patient with precise, small medication doses with both human and veterinary drug library capabilities. The Medfusion 4000 boasts the same impressive features as the 3500 with the added ease of wireless drug capabilities.

Warranty: 6 Months.

Note: The following error codes are used to indicate a problem.

  • Motor Rate Error.
  • Super Cap Post.
  • Force Sensor Bridge Test.
  • Motor Not Running.
  • Pharmguard Data Transfer Recommended.
  • Primary Audible Alarm Post.
  • Clutch/Plunger.

Smiths Medical Medfusion 4000 Features

  • Delivers precise infusion volumes with ± 2% accuracy with delivery rates as low as 0.01 ml/hr and up to 1,130 ml/hr.
  • Built-in drug libraries reduce patient risk.
  • Always on safety mode.
  • PharmGuard Server Software allows you to effortlessly connect to your wireless network.
  • Arrives to you patient-ready.

Smiths Medical Medfusion 4000 Specifications

  • Minimum Increment of Resolution: 0.01 ml/hr.
  • Size (Pump Only): 10.5" wide x 6.2" high x 5.7" deep (27 cm x 16 cm x 14.5 cm).
  • Weight: 4.54 lb (2.04 kg).
  • Classification: Type CF (protection from electric shock).
  • Moisture Protection: IPX3 (sprayproof).
  • Pump Alarms: Syringe empty, syringe near empty, syringe not loaded properly, incorrect syringe size, infusion complete, KVO, battery low/damaged/not working, incorrect calculation, (value) out of range, occlusion/fluid restricted/rate reduced/pressure increasing, pump stopped, system fault, system advisory (set time/date, maintenance recommended, data corrupted).
  • Bolus Volume at Occlusion Release (Typical Values): Variable, dependent on infusion variables and syringe in use. Typical values obtained when testing a pump, using a BD 20 ml syringe at intermediate (5 ml/hr) rate.
    • Bolus after occlusion at minimum selectable occlusion alarm setting (very low): 0.0454 ml.
    • Bolus after occlusion at maximum selectable occlusion alarm setting (high): 0.0815 ml.
  • Power Source:
    • Internal Battery: Rechargeable (lithium-ion).
    • AC Power: 100 - 240 VAC, 50/60 Hz, 42 VA, Safety Class II - Type CF with functional earth conductor.
  • Battery Life: 400 charge cycle counts minimum.
  • Battery Longevity: 10 hours typical at 5.0 ml/hr with 60 ml syringe (from fully charged battery).
  • Operating Conditions:
    • Temperature: 5° to 40° C (40° to 104° F).
    • Relative Humidity: 20 to 95% non-condensing.
    • Ambient Pressure: 70 kPa to 106 kPa (10.2 psia to 15.4 psia).
  • Infusion Back Pressure: -100 mmHg tro 300 mmHg.
  • Storage/Transportation Conditions:
    • Temperature: 20° to 50° C (-4° to 122° F).
    • Relative Humidity: 20% to 95% non-condensing.
    • Ambient Pressure: 70 kPa to 106 kPa (10.2 psia to 15.4 psia).
  • Delivery Accuracy: Nominal ± 2% (± syringe accuracy) for infusion back pressures of -100 mmHg to 300 mmHg.
  • Occlusion Alarm: For 1 ml syringes the occlusion limit is fixed at very high. Very high (1 ml syringe only, not selectable): 50 psi (2585 mmHg) (345 kPa).
  • Maximum Volume Infused Under Single Fault Conditions:1/100th of the syringe size by volume.
  • Maximum Delivery Rate During Bolus: The configured maximum rate at which a bolus or loading dose can be delivered is syringe size x 5 ml/hr, syringe size x 10 ml/hr, or syringe size max ml/hr, whichever is lower.
  • Maximum Delivery Rate During Prime: The priming delivery rate is 300 ml/hr or the default maximum bolus rate for the syringe size being used (syringe size x 5 ml/hr, syringe size x 10 ml/hr, or syringe size max ml/hr, whichever is lower).
  • Infusion Rate Range: 0.01 ml/hr to 1,130 ml/hr in increments of 0.01/0.1 ml/hr (depending on syringe size/rate).
  • Bolus Volume Range: Volume is limited to the maximum fill volume of the current syringe size and minimum volume is 1/600th the syringe size.
  • User-Defined Libraries: Standard libraries are organized on a per profile basis. Each profile allows up to eight library categories with up to 36 drug programs each, for a total of 288 entries per profile. One "quick library" per profile for rapid setup.

Smiths Medical Medfusion 4000 Literature

Smiths Medical Medfusion 4000 Operator's Manual

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

You may also like

Recently viewed

Free Shipping

on all parcel shipped orders to the contiguous U.S.

Free Returns

on most items returned within 30 days of receipt

Top-notch Support

We're dedicated to providing the best service in the industry

Secure payments

Shop worry-free with our ultra-safe online checkout system