Regular price$22,330.00 Sale price$18,672.58
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Quinton Q-Stress Cardiac Stress System includes a PC workstation with keyboard and mouse configured with cardiac stress application software (Version 6), 24" wide-screen color monitor, Z200+ thermal printer (with two starter packs of full-grid 8" paper), AM12Q Wired Acquisition Module with Trigger Module, isolation transformer, system cart with base, keyboard tray, storage shelf, large storage drawer, side storage pocket, 10-lead ECG patient cable with leadwires, stress belt to support the patient cable, local area network (LAN) support, and US/Canada power cord.

Warranty: 13 Months - Parts and Labor.

The Q-Stress is designed to perform a variety of functions, from routine exams to complex cardiac evaluations. The Cardiac Stress System is a customizable, scalable platform offering highly flexible configurations that can be adapted for each application, user, and site.

Features

Quinton Q-Stress Cardiac Stress System Features

  • VERITAS algorithm offers exceptional accuracy in real-time ST-Segment Monitoring, arrhythmia detection, and resting ECG interpretation.
  • Source Consistency Filter removes noise and baseline artifact offering an accurate picture of the ECG waveform.
  • Real-time full disclosure lets you review historical ECG data throughout the exam.
  • Connected workflows help you improve patient care and information access.
  • Flexible user configurations tailor over-reads, billing, and data storage to your workflow.
  • 12-lead ECG interpretation for adults, adolescents, and children.
  • Communicate bidirectionally using HL7 or DICOM to reduce errors while providing an electronic, editable format to your team.
  • Label, store, print, and review events on the fly and include them in final report.
  • Wireless Acquisition Module (WAM) digitally transmits ECG data to help make exams easier and more comfortable for patients.
  • AM12Q Wired Acquisition Module with Trigger Module for TTL/analog signal output and low voltage treadmill.

Specifications

Quinton Q-Stress Cardiac Stress System Specifications

  • Power Requirements: 100/120 VAC, 50/60 Hz, 2.5 A nominal; 200/240 VAC, 50/60 Hz, 1.3 A nominal.
  • Operating System: Microsoft Windows 10 Pro 64-bit.
  • Protocols:
    • Standard: Bruce, Modified Bruce, Modified Balke, Naughton, USAF/SAM 2.0, USAF/SAM 3.3, Ramped-low, Ramped-medium, Ramped-high, Time-Ramp, and METs Ramp, Astrand (ergometer), pharmacological, and more.
    • Custom: Up to 100 custom protocols assorted.
  • Front-End Module:
    • AM12Q with AHA 10-electrode pinch or snap connectors.
    • AM12Q with IEC 10-electrode-pinch or snap connectors.
    • WAM module for wireless ECG acquisition with AHA 10-electrode-pinch connectors.
    • WAM module for wireless ECG acquisition with IEC 10-electrode-pinch connectors.
  • ECG:
    • Lead Groups: Cabrera 12-lead.
    • Display Format: 3, 6, 6 x 2, or 12 x 1 channels.
    • Performance Standard: IEC 60601-2-25: gain accuracy, frequency response, CMRR, system noise, dynamic range, and input impedance.
  • Display and Analysis Filters: Source Consistency Filter (SCF), muscle artifact, baseline wander, 40 Hz low pass, line frequency.
  • Reports:
    • In-Test: 12-Lead, average beat report, 1-page write screen, continuous rhythm, arrhythmia events.
    • Final: Summary, tabular, worst case, average beats by stage or by minute, in-test ECG reports, trend graphs and peak exercise. Reports can be viewed, printed, saved in PDF format, emailed or exported in PDF, XML, and DICOM.
    • Custom: Unlimited customizable reports.
  • Outputs: TTL pulse and analog signals for QRS detection synchronization using any ECG lead.
  • External Device Interfaces:
    • Treadmills: Trackmaster TMX428 and TMX425.
    • Ergometers: Compatible with Ergoline and Lode communication protocols.
    • Blood Pressure Monitors: SunTech Tango+ and Tango M2.
  • Printers:
    • Thermal: High-resolution Z200+ with automatic feed and continuous printing capability (requires additional network port).
    • Laser: Optional compact HP M501dn laser printer with high-quality print (recommended).
    • Paper: 8.5" x 11" (letter) or 210 mm x 300 mm (A4).
  • Network Interface: Microsoft-compatible networking for storage, distribution, and email; 100 Mbps connection or better is required.
  • Paper: Smart (210 x 280 mm), perforated Z-fold thermal cued paper with full grid; 250 sheets stored in paper tray.
  • Export/Communication Protocol/Format: TCP/IP, PDF, XML, HL7, DICOM.
  • Remote Technical Service Interface: Remote service increases system uptime availability and decreases the user's requirement to assist the troubleshooting process. Available via network or desktop connections (only in the US).
  • Display: 24" (609 mm) flat panel LCD (24" touchscreen display is optional).
  • System Dimensions: 22.5" (D) x 24.6" (W) x 62.5" (H) (57 cm x 63 cm x 159 cm).
  • Weight: Approximately 270 lb (122.5 kg).

Configurations

Quinton Q-Stress Cardiac Stress System Configurations

  • #QS6-MLTCX: Mid Level - With LCD Screen and PDF/XML Connectivity.
  • #QS6-MLTC1: Mid Level - With LCD Screen, Treadmill, and PDF/XML Connectivity.
  • #QS6-ATTDX: Pro Level - With Touch Monitor and DICOM Connectivity.
  • #QS6-ATTD1: Pro Level - With Touch Monitor, Treadmill, and DICOM Connectivity.

Accessories

Quinton Q-Stress Cardiac Stress System Accessories

The following accessories are compatible and commonly purchased with the Q-Stress Cardiac Stress System:

  • #4100-036-51: WAM Kit with AHA Short Lead Set.
  • #9100-026-60: Thermal Paper - 8.5" x 11".
  • #9911-023-33: SunTech Tango Mount Kit for use with ELO 24" Touch Monitor.
  • #9922-017-52: SunTech Tango+ and Tango M2 SpO2 option.
  • #9922-019-50: SunTech Tango M2 BP Monitor Kit.
  • Q-Stress Protection+ Smartcare Service 3-Year Program:
    • #S9-QS-PROPLUS-PS: For Standard Systems.
    • #S9-QSTM-PROPL-PS: For Systems with Treadmill.

Frequently asked questions

Is this system capable of complex evaluations?

Yes, the Quinton Q-Stress Cardiac Stress System is designed as a highly capable and scalable platform for comprehensive cardiac evaluations, ranging from routine exams to complex clinical assessments.

Its capacity for high-fidelity analysis is driven by several key features:

  • Advanced Analysis: Utilizes the proprietary VERITAS Algorithm for exceptional accuracy in real-time ST-Segment Monitoring, arrhythmia detection, and precise 12-lead ECG interpretation for all age groups.
  • Superior Signal Integrity: The Source Consistency Filter (SCF) ensures a clean, accurate ECG waveform by actively removing noise and baseline artifacts.
  • Workflow Flexibility: Supports up to 100 custom protocols in addition to numerous standard protocols (Bruce, Naughton, etc.), allowing for tailored, complex evaluations.
  • Full Disclosure Review: Clinicians benefit from real-time full disclosure capabilities, enabling continuous retrospective review of historical ECG data captured throughout the entire examination session.
What does the advanced VERITAS algorithm analyze?

The VERITAS algorithm is central to the Quinton Q-Stress System’s performance, providing exceptional analytical accuracy during cardiac stress evaluations. It performs comprehensive, real-time analysis across 12 leads, specializing in:

  • Real-time ST-Segment Monitoring: Essential for tracking potential myocardial ischemia throughout the stress test.
  • Arrhythmia Detection: Provides highly accurate identification of irregular heart rhythms.
  • 12-Lead ECG Interpretation: Delivers reliable diagnostic interpretation for a wide patient demographic, including adults, adolescents, and children.
How does the Source Consistency Filter improve ECG quality?

The Source Consistency Filter (SCF) enhances ECG waveform quality by effectively removing noise and baseline artifacts. This ensures a clearer and more accurate analysis of the ECG data, improving diagnostic precision.

Does the Cardiac Stress System use a modern operating system?

The Quinton Q-Stress Cardiac Stress System operates on Microsoft Windows 10 Pro 64-bit, providing a familiar and stable platform for comprehensive cardiac evaluations.

What standard stress test protocols are included?

The Quinton Q-Stress Cardiac Stress System supports a wide variety of standard protocols for cardiac evaluation, ensuring flexibility across different clinical needs.These include:

  • Bruce
  • Modified Bruce
  • Modified Balke
  • Naughton
  • USAF/SAM 2.0 and USAF/SAM 3.3
  • Ramped protocols (Ramped-low, Ramped-medium, Ramped-high, Time-Ramp, METs Ramp)
  • Astrand (ergometer)
  • Pharmacological

For enhanced flexibility, the system also allows clinicians to configure and store up to 100 user-defined custom protocols.

Does the system use high-quality ECG acquisition?

Yes, the Quinton Q-Stress system is engineered for superior signal integrity during cardiac stress testing. It achieves high-quality acquisition through specialized hardware and software:

  • Acquisition Module: The system includes the AM12Q Wired Acquisition Module with a Trigger Module.
  • Advanced Analysis: It uses the proprietary VERITAS Algorithm, providing exceptional accuracy for real-time ST-Segment monitoring, arrhythmia detection, and detailed 12-lead ECG interpretation for all age groups.
  • Signal Clarity: The system incorporates the Source Consistency Filter (SCF) and other analysis filters (e.g., muscle artifact, baseline wander) to actively remove noise and artifact, ensuring an accurate and clean ECG waveform.
  • Performance Standard: The ECG performance meets the requirements of the IEC 60601-2-25 standard.
Which external devices integrate with the system?

The Quinton Q-Stress Cardiac Stress System is designed for seamless integration with key external devices used during cardiac evaluations.

The system supports communication protocols for the following types of equipment:

  • Treadmills: The system interfaces directly with Trackmaster TMX428 and TMX425 models.
  • Ergometers: Compatibility is ensured through support for Ergoline and Lode communication protocols.
  • Blood Pressure Monitors: Integration is supported for SunTech Tango+ and Tango M2 BP monitors.
Does the system include HL7 and DICOM connectivity?

Yes, the Quinton Q-Stress system is engineered for a connected clinical workflow and supports robust data integration protocols.

  • Integration: The system supports bidirectional communication via industry-standard HL7 or DICOM for seamless exchange with Electronic Health Records (EHRs) and other clinical systems.
  • Data Export: Comprehensive final reports (Summary, trend graphs, etc.) can be exported in multiple electronic formats, including PDF, XML, and DICOM.
  • Configuration Note: While LAN support is standard, specific configurations (such as Pro Level variants) or add-on licenses may be required to enable full DICOM functionality.
What configurations does the Q-Stress system offer?

The Quinton Q-Stress System is a highly flexible and scalable platform that can be tailored to meet diverse clinical workflow needs. The core system is configurable across several key components:

  • Configuration Level: The system is available in Mid Level and Pro Level options, which generally determine the available features and advanced connectivity.
  • Display Type: You can choose between the standard 24-inch flat panel LCD monitor or upgrade to an optional 24-inch touchscreen display.
  • Connectivity: Standard configurations support PDF/XML export. For advanced integration with Electronic Health Records (EHR) and PACS systems, the Pro Level offers support for HL7 or DICOM bi-directional communication protocols.
  • Peripherals: The system can be configured to include a compatible treadmill, allowing for comprehensive exercise stress testing (compatible with models like the Trackmaster TMX428 and TMX425).
Does the system support HL7 or DICOM connectivity?

Yes, the Quinton Q-Stress system is engineered for connected workflows and robust data exchange using industry-standard protocols.

Key connectivity features include:

  • Bidirectional Communication: The system supports both HL7 and DICOM protocols. This facilitates electronic data management, reduces manual entry errors, and enables seamless report sharing across your Electronic Health Record (EHR) system. (Note: DICOM support is available in Pro Level configurations).
  • Network Requirement: Connectivity is supported via your Local Area Network (LAN), requiring a minimum connection speed of 100 Mbps or better.
  • Reporting: Final diagnostic reports are highly customizable and can be exported in formats including PDF, XML, and DICOM.