-
Condition:
-
Country of Origin: USA
-
Warranty:
- Weight: 270.0 lb
- Designed to perform a variety of functions, from routine exams to complex cardiac evaluations
- Source Consistency Filter designed to remove noise and maintain ECG integrity
- Examine historical ECG data throughout the exam with real-time full disclosure
- VERITAS algorithm provides 12-lead ECG interpretation for adults, adolescents, and children
-
Learn more:
-
MFR:
Quinton
Ships from Manufacturer
-
MPN: QS6-MLTCX
- Phone: (800) 535-6663
+Shipping
Shop with Confidence
Sales Tax Exemption
+Dedicated Account Managers
Frequently asked questions
Is this system capable of complex evaluations?
Yes, the Quinton Q-Stress Cardiac Stress System is designed as a highly capable and scalable platform for comprehensive cardiac evaluations, ranging from routine exams to complex clinical assessments.
Its capacity for high-fidelity analysis is driven by several key features:
- Advanced Analysis: Utilizes the proprietary VERITAS Algorithm for exceptional accuracy in real-time ST-Segment Monitoring, arrhythmia detection, and precise 12-lead ECG interpretation for all age groups.
- Superior Signal Integrity: The Source Consistency Filter (SCF) ensures a clean, accurate ECG waveform by actively removing noise and baseline artifacts.
- Workflow Flexibility: Supports up to 100 custom protocols in addition to numerous standard protocols (Bruce, Naughton, etc.), allowing for tailored, complex evaluations.
- Full Disclosure Review: Clinicians benefit from real-time full disclosure capabilities, enabling continuous retrospective review of historical ECG data captured throughout the entire examination session.
What does the advanced VERITAS algorithm analyze?
The VERITAS algorithm is central to the Quinton Q-Stress System’s performance, providing exceptional analytical accuracy during cardiac stress evaluations. It performs comprehensive, real-time analysis across 12 leads, specializing in:
- Real-time ST-Segment Monitoring: Essential for tracking potential myocardial ischemia throughout the stress test.
- Arrhythmia Detection: Provides highly accurate identification of irregular heart rhythms.
- 12-Lead ECG Interpretation: Delivers reliable diagnostic interpretation for a wide patient demographic, including adults, adolescents, and children.
How does the Source Consistency Filter improve ECG quality?
The Source Consistency Filter (SCF) enhances ECG waveform quality by effectively removing noise and baseline artifacts. This ensures a clearer and more accurate analysis of the ECG data, improving diagnostic precision.
Does the Cardiac Stress System use a modern operating system?
The Quinton Q-Stress Cardiac Stress System operates on Microsoft Windows 10 Pro 64-bit, providing a familiar and stable platform for comprehensive cardiac evaluations.
What standard stress test protocols are included?
The Quinton Q-Stress Cardiac Stress System supports a wide variety of standard protocols for cardiac evaluation, ensuring flexibility across different clinical needs.These include:
- Bruce
- Modified Bruce
- Modified Balke
- Naughton
- USAF/SAM 2.0 and USAF/SAM 3.3
- Ramped protocols (Ramped-low, Ramped-medium, Ramped-high, Time-Ramp, METs Ramp)
- Astrand (ergometer)
- Pharmacological
For enhanced flexibility, the system also allows clinicians to configure and store up to 100 user-defined custom protocols.
Does the system use high-quality ECG acquisition?
Yes, the Quinton Q-Stress system is engineered for superior signal integrity during cardiac stress testing. It achieves high-quality acquisition through specialized hardware and software:
- Acquisition Module: The system includes the AM12Q Wired Acquisition Module with a Trigger Module.
- Advanced Analysis: It uses the proprietary VERITAS Algorithm, providing exceptional accuracy for real-time ST-Segment monitoring, arrhythmia detection, and detailed 12-lead ECG interpretation for all age groups.
- Signal Clarity: The system incorporates the Source Consistency Filter (SCF) and other analysis filters (e.g., muscle artifact, baseline wander) to actively remove noise and artifact, ensuring an accurate and clean ECG waveform.
- Performance Standard: The ECG performance meets the requirements of the IEC 60601-2-25 standard.
Which external devices integrate with the system?
The Quinton Q-Stress Cardiac Stress System is designed for seamless integration with key external devices used during cardiac evaluations.
The system supports communication protocols for the following types of equipment:
- Treadmills: The system interfaces directly with Trackmaster TMX428 and TMX425 models.
- Ergometers: Compatibility is ensured through support for Ergoline and Lode communication protocols.
- Blood Pressure Monitors: Integration is supported for SunTech Tango+ and Tango M2 BP monitors.
Does the system include HL7 and DICOM connectivity?
Yes, the Quinton Q-Stress system is engineered for a connected clinical workflow and supports robust data integration protocols.
- Integration: The system supports bidirectional communication via industry-standard HL7 or DICOM for seamless exchange with Electronic Health Records (EHRs) and other clinical systems.
- Data Export: Comprehensive final reports (Summary, trend graphs, etc.) can be exported in multiple electronic formats, including PDF, XML, and DICOM.
- Configuration Note: While LAN support is standard, specific configurations (such as Pro Level variants) or add-on licenses may be required to enable full DICOM functionality.
What configurations does the Q-Stress system offer?
The Quinton Q-Stress System is a highly flexible and scalable platform that can be tailored to meet diverse clinical workflow needs. The core system is configurable across several key components:
- Configuration Level: The system is available in Mid Level and Pro Level options, which generally determine the available features and advanced connectivity.
- Display Type: You can choose between the standard 24-inch flat panel LCD monitor or upgrade to an optional 24-inch touchscreen display.
- Connectivity: Standard configurations support PDF/XML export. For advanced integration with Electronic Health Records (EHR) and PACS systems, the Pro Level offers support for HL7 or DICOM bi-directional communication protocols.
- Peripherals: The system can be configured to include a compatible treadmill, allowing for comprehensive exercise stress testing (compatible with models like the Trackmaster TMX428 and TMX425).
Does the system support HL7 or DICOM connectivity?
Yes, the Quinton Q-Stress system is engineered for connected workflows and robust data exchange using industry-standard protocols.
Key connectivity features include:
- Bidirectional Communication: The system supports both HL7 and DICOM protocols. This facilitates electronic data management, reduces manual entry errors, and enables seamless report sharing across your Electronic Health Record (EHR) system. (Note: DICOM support is available in Pro Level configurations).
- Network Requirement: Connectivity is supported via your Local Area Network (LAN), requiring a minimum connection speed of 100 Mbps or better.
- Reporting: Final diagnostic reports are highly customizable and can be exported in formats including PDF, XML, and DICOM.
Quinton Q-Stress Cardiac Stress System