{"product_id":"peripheral-iv-catheter-prevent-sls-20-gauge-1-inch-polyurethane-straight-hub-non-blood-control-sliding-safety","title":"Peripheral IV Catheter Prevent SLS 20 Gauge 1 Inch Polyurethane Straight Hub Non Blood Control Sliding Safety","description":"\u003cul\u003e\n\u003cli\u003ePrevent SLS Sliding Safety IV Catheters\u003c\/li\u003e\n\u003cli\u003eErgonomically designed with slide activation featuring corrugated, contoured grips, smooth bottom side, and push-off tabs that allow one-handed insertion and catheter advancement\u003c\/li\u003e\n\u003cli\u003eSlide-style safety mechanism retracts needle fully and safely into the catheter body\u003c\/li\u003e\n\u003cli\u003eStandard straight hub design\u003c\/li\u003e\n\u003cli\u003eAudible -click- lock confirmation to ensure needle is safely encapsulated in the catheter body for safety through point of disposal\u003c\/li\u003e\n\u003cli\u003eRidged catheter hub for enhanced grip and stability when connecting I.V. administration lines\u003c\/li\u003e\n\u003cli\u003eNeedle shield encases the needle as catheter is advanced, promoting needlestick safety and reducing exposure to bloodborne pathogens\u003c\/li\u003e\n\u003cli\u003eGently tapered catheter tip requires less force and smooths transition from needle to catheter during insertion, easing the task for the clinician and reducing trauma for the patient\u003c\/li\u003e\n\u003cli\u003eTriple-facet, back-cut, and polished beveled needle for multi-angle insertion using one- or two-handed techniques according to clinician preference\u003c\/li\u003e\n\u003cli\u003eBevel design allows visual alignment confirming needled is facing upward and leading edge of canula is positioned just shy of the needle-point bevel\u003c\/li\u003e\n\u003cli\u003eEnhanced flashback design provide optimal visualization of blood return along the needle shaft allowing administrator immediate confirmation of vessel entry\u003c\/li\u003e\n\u003cli\u003eISO-compliant, color-coded catheter hub and packaging for easy identification of needle gauge size\u003c\/li\u003e\n\u003cli\u003ePolyurethane catheter construction with medical-grade, ground stainless steel needle\u003c\/li\u003e\n\u003cli\u003eRadiopaque materials allow use during x-rays or other form of radiation\u003c\/li\u003e\n\u003cli\u003eTapered catheter requires less force\u003c\/li\u003e\n\u003cli\u003eDesigned for end-user familiarity of sliding activation method with design improvements\u003c\/li\u003e\n\u003cli\u003eEquipped with safety cap and individually wrapped for safety and sterility\u003c\/li\u003e\n\u003cli\u003eIndicated to sample blood or administer fluids intravenously\u003c\/li\u003e\n\u003cli\u003eNon-pyrogenic, DEHP-free, and not made with natural rubber latex\u003c\/li\u003e\n\u003cli\u003ePackaged: 1 Per Pack, 50 Per Box, 4 Boxes Per Case\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct Specs\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem Number\u003c\/th\u003e\n\u003ctd\u003e1240141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Number\u003c\/th\u003e\n\u003ctd\u003e200-IVS201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUOM\u003c\/th\u003e\n\u003ctd\u003eCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel 1 Family Description\u003c\/th\u003e\n\u003ctd\u003eNursing and Surgical Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel 2 Category Description\u003c\/th\u003e\n\u003ctd\u003eIV Therapy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel 3 Group Description\u003c\/th\u003e\n\u003ctd\u003eIV Catheters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel 4 Sub-Category Description\u003c\/th\u003e\n\u003ctd\u003eSafety Iv Catheters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003ePeripheral IV Catheter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlood Control\u003c\/th\u003e\n\u003ctd\u003eNon Blood Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003ePrevent SLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBuy American Act (BAA) Compliant\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatheter Length\u003c\/th\u003e\n\u003ctd\u003e1 Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatheter Material\u003c\/th\u003e\n\u003ctd\u003ePolyurethane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eColor Code\u003c\/th\u003e\n\u003ctd\u003ePink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of Origin\u003c\/th\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDEHP Indicator\u003c\/th\u003e\n\u003ctd\u003eDEHP-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow Rate\u003c\/th\u003e\n\u003ctd\u003e61 mL \/ min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGauge\u003c\/th\u003e\n\u003ctd\u003e20 Gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHCPCS\u003c\/th\u003e\n\u003ctd\u003eC1769\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHub Material\u003c\/th\u003e\n\u003ctd\u003ePlastic Hub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHub Type\u003c\/th\u003e\n\u003ctd\u003eStraight Hub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMcKesson Brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer #\u003c\/th\u003e\n\u003ctd\u003e200-IVS201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMcKesson #\u003c\/th\u003e\n\u003ctd\u003e1240141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Point Style\u003c\/th\u003e\n\u003ctd\u003eBevel Needle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Ports\u003c\/th\u003e\n\u003ctd\u003eWithout Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePort Type\u003c\/th\u003e\n\u003ctd\u003eWithout Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure Rating\u003c\/th\u003e\n\u003ctd\u003e300 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Activation\u003c\/th\u003e\n\u003ctd\u003eSliding Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Feature\u003c\/th\u003e\n\u003ctd\u003eSliding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSterility\u003c\/th\u003e\n\u003ctd\u003eSterile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrade Agreement Act (TAA) Compliant\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTubing Diameter\u003c\/th\u003e\n\u003ctd\u003e1.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUNSPSC Code\u003c\/th\u003e\n\u003ctd\u003e42221512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUsage\u003c\/th\u003e\n\u003ctd\u003eDisposable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVessel Entry Confirmation\u003c\/th\u003e\n\u003ctd\u003eFlashback Chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eX-Ray Compatibility\u003c\/th\u003e\n\u003ctd\u003eRadiopaque\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"McKesson Brand","offers":[{"title":"Default Title","offer_id":42967751426125,"sku":"MKS-200-IVS201","price":449.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1046\/1086\/files\/1240141_right_4ad75258-7ac3-4874-b86a-b0220436efb9.jpg?v=1780343064","url":"https:\/\/mfimedical.com\/products\/peripheral-iv-catheter-prevent-sls-20-gauge-1-inch-polyurethane-straight-hub-non-blood-control-sliding-safety","provider":"MFI Medical","version":"1.0","type":"link"}