Sale price$108.00
Earn 108 points
Select a Configuration

Ships from Manufacturer

Est. Delivery: 

Shop with Confidence

Description

This Maxtec MAX-12 O2 Cell is an FiO2 (Fraction of Inspired Oxygen) Sensor that is compatible with a variety of systems. Primarily used with Ventilator Machines and O2 Monitors/ Analyzers; check below for specific compatibility information.

*Note: Can only be shipped within the U.S.

Warranty: 16 Month Shelf Life.

Maxtec MAX-12 O2 Cell Specifications:


  • Compatible with:
    • Analytical Industries.
    • Bird Avea Ventilator.
    • Citi Technologies.
    • Datascope 0600-00-0002.
    • Envitec.
    • EME Hamilton Medical: Viasys Arabella, Galileo, Raphael, Aladdin, 51254, Carefusion Viasys Avea 16448.
    • Emerson Infant Flow.
    • Datex-Ohmeda.
    • Hamilton Instruments: G5, Raphael, Arabella, Multinex, Analyser, Aladdin, Galileo, 51254, 396008, 396009.
    • Hudson: 5556.
    • IMT: PF300.
    • Infrasonics: Adult Star 601T.
    • Maxtec.
    • MSA.
    • Nuova.
    • Puritan Bennett: NP 840 Ventilator 4-074925-00.
    • Sensidyne: Acutonic Hi Frequency Jet Ventilator, 00M102.
    • Siemens: Servo 900C, 900D, 900E, Servo 300, 300A, SV 300, Servo 700, 710, SV900, V710, C/D, 9000, Infinity Delta.
    • Spacelabs: Capnograph, 90513.
    • Taema: Cesar 2, Horus 4, YR049700.
    • Teledyne TED 160, TED 190.
    • Viamed.
  • Equivalent to:
    • Analytical Industries: PSR-11-917-J, PSR-11-917-M
    • Ceramatec: CAG-12.
    • City Technologies: MOX-9, R-24.
    • Envitec: OOM-202.
    • Datex Ohmeda: 6051-0000-222.
    • Hamilton Medical: 396008, 396009, HM-12.
    • Hudson RCI: 5566, V-12.
    • Integral Process: 65016.
    • International Technologies: M-04.
    • IMT Medical: PF300.
    • Maxtec: MAX-12 R109P45.
    • Mercury Medical: 10-103-06.
    • MSA: 472062,470644.
    • Nuova: E-17/M.
    • Ohio Medical: 472062, 470644.
    • Pacifitech: PT-12A.
    • Siemens: 9004979-E347E, 6419332-E380E.
    • Sensidyne: SV-12A.
    • SensorTech: ST-01.
    • Spacelabs: 90513.
    • Taema: YR049700.
    • Teledyne: R24 MED, B-62321.
    • Ventrex: V-12A.
    • Viamed: R-24Med.
    • VTI Vascular Technology: 103100.
  • G0-040 (Maxtec Equivalent) Specifications:
    • Response Time: < 12 seconds.
    • Connector Type: 3-Pin Molex gold plated.
  • R109P45 (Maxtec) Specifications:
    • Output: 14.5 ± 1.5 mV.
    • Response Time: ‰¤ 13 seconds.
    • Linearity: < 2% relative.


Maxtec MAX-12 O2 Cell Configurations:


  • G0-040: MAX-12 Cell Equivalent manufactured by Cables and Sensors.
  • R109P45: Maxtec MAX-12 Cell manufactured by Maxtec.


    Maxtec MAX-12 O2 Cell Literature:


    Maxtec KOH Oxygen Sensors Safety Data Sheet

    Maxtec MAX-12 Oxygen Cell Specifications Sheet

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)